Fisher LNS-W03 Lens Replacement and Installation Procedure Type 1 Cabinet, Fig-1, Fig-2, Fig-3

Page 3

LENS REPLACEMENT AND INSTALLATION PROCEDURE (Type 1 Cabinet)

Perform the steps

1

to

5

for lens replacement and installation.

First set the lens at the center position with lens shift adjustment.

1 REMOVE THE LENS COVER. (See figure-1)

1.Remove screws A (2 screws).

2.Pull down the lower lens cover while pushing the part D, then remove it.

3.Remove screws B (2 screws).

4.Remove screws C (2 screws) and remove upper lens cover.

2

IN CASE OF MODEL WITHOUT LENS

UPPER LENS COVER

 

C

 

 

 

B

D

D

Fig-1

A

LOWER LENS COVER

REMOVE THE COVER PLATE OF THE LENS COVER. (See figure-2)

Remove 2 screws and pull down the plate.

(At the step 4 , insert the light-block sheet in the same position as the removed cover plate has been placed. Two screws are not used.)

Disconnect the Lens Shift connector

SCREWS

("K16A") from circuit board. (See Fig. 3.)

 

 

COVER PLATE

IN CASE OF MODEL WITH LENS

Fig-2

REMOVE THE LENS. (See figure-3.)

1.Disconnect the Lens Shift connector “K16A” from circuit board.

2.Disconnect the Zoom and Focus con- nector “K16B” from circuit board.

3.Loosen the A, B wire holder and remove the lens motor lead.

4.Remove screws D (4 screws) which fastens the lens and remove the lens.

Figure shown inside of the cabinet.

LENS MOTOR

(D)(D)

A

(D)(D)

B

A

LENS

MOTOR LEAD

Fig-3

CONNECTORS " K16A" and " K16B"

-2-

Image 3
Contents Type of the Cabinet 1 See Type of the Cabinet 2 See Lens Replacement Installation ProceduresBe Sure to Check for Safety Fig-3 Lens Replacement and Installation Procedure Type 1 CabinetFig-1 Fig-2Fig-5 Fig-4Lens Replacement and Installation Procedure Type 2 Cabinet Fig-6 Fig-7 Focus Adjustmentご注意:レンズを取り付けるまえに 梱包には以下の部品が入っています。 ・レンズ本体 ・専用ドライバー ・遮光プレート 取り付け作業上の注意レンズなしモデルの場合 レンズカバーのカバープレートを外します。(図2参照) レンズの交換と取り付けかた (キャビネット形状 1の場合)レンズの交換・取り付けは 1 ~ 5 の手順で行います。 レンズカバーを外す。(図1参照)レンズカバーを取り付けます。(図6参照) レンズを取り付けます。(図4参照)遮光プレートを取り付けます。(図5参照) フォーカスを合わせます。レンズカバー下を外す。(図 2参照) レンズの交換と取り付けかた (キャビネット形状 2の場合)レンズの交換・取り付けは 1 ~ 7 の手順で行います。 レンズカバー上を外す。(図1参照)レンズシフトコネクターを取り外します。(図4参照) レンズを取り付けます。(図5参照)遮光プレートを取り付けます。(図6参照) レンズを取り付けます。(図7参照) フォーカス調整のしかた。

LNS-W03 specifications

The Fisher LNS-W03 is a state-of-the-art flow control valve designed for gas and liquid applications in various industrial sectors. Known for its robust design and precision engineering, the LNS-W03 ensures optimal performance and reliability in demanding environments.

One of the main features of the LNS-W03 is its exceptional flow control capabilities. The valve employs a unique flow path design that minimizes pressure drops while maximizing flow rates. This characteristic makes it ideal for applications requiring a high degree of accuracy and efficiency. The LNS-W03 is available in a range of sizes and configurations, allowing users to tailor it to specific requirements.

The Fisher LNS-W03 utilizes advanced technologies to enhance its performance. It features a fast-acting actuator that allows for quick and precise adjustments in flow, reducing response times and improving overall system efficiency. This is particularly beneficial in processes where rapid changes in flow control are necessary.

The valve is constructed using high-quality materials that provide durability and corrosion resistance. This is critical in harsh industrial environments where exposure to various chemicals and extreme temperatures is common. Additionally, the LNS-W03 has a low maintenance design, reducing downtime and operational costs.

Another notable characteristic of the LNS-W03 is its integration with smart technology. The valve can be equipped with electronic monitoring systems that provide real-time data on flow rates, pressures, and other vital metrics. This capability allows for better predictive maintenance and operational efficiency, as users can identify potential issues before they escalate.

The Fisher LNS-W03 is designed with safety in mind. It incorporates features such as a fail-safe position and emergency shut-off mechanisms to prevent accidents and ensure safe operation. This commitment to safety makes it suitable for use in critical applications, including oil and gas processing, chemical manufacturing, and water treatment.

In conclusion, the Fisher LNS-W03 flow control valve stands out for its precision, durability, and incorporation of advanced technologies. Its ability to deliver reliable performance in challenging conditions, coupled with its smart technology compatibility, positions it as an essential component in modern industrial flow control systems. Whether used in a manufacturing plant, a processing facility, or any other application requiring meticulous flow management, the LNS-W03 is a valve that delivers superior performance and peace of mind.