Bosch Appliances manual Overview D8125INV Overview, Features, Specifications

Page 9

D8125INV

Overview

2.0D8125INV Overview

2.1Features

Compatible with Bosch Security Systems D9412GV2, D7412GV2, D7212GV2, D9412G, D7412G, D7212G, D9412, D7412, D7212, and D9112 Control Panels. (FA113 can not be used on the D7212GV2 andD7212G panels)

Menu driven User Interface

On the D9412GV2, D9412G, D9412, and D9112, the D8125INV supports up to 2 Inovonics FA400 Receivers (with a maximum of 238 transmitters [119 per bus])

On the D7412GV2, D7412G, and D7412, the D8125INV supports up to 2 Invonics FA400 Receivers (with a maximum of 67 transmitters)

On the D7212GV2 and D7212G, the D8125INV supports up to 2 Invonics FA400 Receivers (with up to 32 transmitters in the same location).

An unlimited number of FA113 Wireless Keyfobs can be added

Used for diagnostic functions to troubleshoot system RF Transmitters

Programmable system-wide supervision time interval and individual transmitter check-in time

Programmable transmitter configuration (Normally Open/Normally Closed, Internal/External Contact, EOL Resistor)

2.2Specifications

User Interface:

LCD Display

 

2 lines by 16 characters, Backlit

 

Keypad

 

0 – 9 numbers

 

 

 

ESC, ENT, PREV, NEXT and DIAG keys

Operating Voltage:

10.2 - 14 VDC supplied by Aux Power from Control Panel or an External

 

Auxiliary Power Supply.

 

Current:

30 mA typical, 45 mA maximum

 

plus ≈ 40 mA for each FA400 receiver

Operating Temperature:

°

° °

°

 

+32 F to +149 F (0 C to +65 C), 93% Relative Humidity

Wiring:

18 AWG or 22 AWG Solid or Stranded. Maximum distance from control

 

panel cannot exceed 5 ft. (1.5 m).

Dimensions (HxWxD):

3.94 in. x 6.5 in. x 1.2 in. (10 cm x 16.6 cm x 3 cm)

Weight:

8.6 oz. (243 g)

 

 

 

 

Table 3: D8125INV Specifications

 

 

 

Operating Voltage:

10.2 VDC to 14 VDC

 

Curent:

40 mA Max.

 

 

 

Wiring:

18 AWG or 22 AWG Solid or Stranded. Maximum distance from D8125INV

 

to FA400 cannot exceed 200 ft. (61 m) or 1000 ft. (305 m) with power supply.

 

Table 4: FA400 Specifications

2.2.1Power

If the D8125INV is powered down and then back up, it may take up to a maximum of 5 minutes (up to 15 minutes for 5 minute Transmitter Check-In Time) for all the transmitters to report back to the D8125INV with their current status. On systems employing fewer transmitters, this time is reduced proportionately.

In addition, when the D8125INV is powered up, all programmed RF points will report Normal until their state is updated.

The D8125INV power should be connected to the control panel using the Aux Power terminals. If the D8125INV were to lose power, the following conditions may result:

All RF points will report to the control panel as missing (trouble/alarm)

D8125INV Operation and Installation Guide

© 2005 Bosch Security Systems

Page 9

49690E

Image 9
Contents Wireless Interface Module D8125INV D8125INV Contents Figures Tables D8125INV FCC Compliance Notice, Part IntroductionOther Literature Referenced Documentation ConventionsTips, Important Notes, Cautions and Warnings Features SpecificationsOverview D8125INV Overview Overview Self-TestingD8125INV Back View System Supervision WatchdogMounting the D8125INV InstallationRefer to and for the proper wiring connections Wiring the D8125INV to the Control Panel and FA400 ReceiverSetting the Jumper for a second receiver D8125INV Quick Startup RecommendationsLabeling the Inovonics Transmitters D8125INV Keypad Operation Initial Power-UpKey Description Key DescriptionsFactory Default Passcode Call for ServiceRF System OK Entering Invalid PasscodesBeginning steps to add/edit/delete an RF Transmitter D8125INV Menu SelectionsInovonics Mode External Contact Internal Fire Normally Point ModeInovonics Transmitter Mode Recommended Mode ValuesFunction Used When… For more information… Menu 1 Add, Edit or Delete RF TransmitterRF Transmitter options Adding a new RF TransmitterD8125INV Adding an existing RF Transmitter Connecting cable To D8125INVProgramming the FA570/FA575 Repeater Deleting an RF TransmitterProgramming the FA113 Keyfob Recommended Point Types/Point Responses Menu 2 Change Installer PasscodeMenu 3 Set System ID Menu 5 Set RF System Supervision Interval Menu 4 Clear EepromRF Diagnostics Function Variable Descriptions Variable DescriptionD8125INV Symptom Diagnosis Remedy TroubleshootingD8125INV Troubleshooting Solutions Low Transmitter Battery ConditionsFA400 Receiver Supervision Missing TransmittersInovonics Frequently Asked Questions D8125INV Power Cycle OperationWhat is temperature range for good operation? Can I externalize an antenna?Does each transmitter need a repeater? D8125INV D8125INV Program Sheet Point TextLocation Or N/C Yes / No D8125INV D8125INV D8125INV

D8125INV specifications

The Bosch Appliances D8125INV is a remarkable addition to the world of high-end kitchen technology, designed to deliver exceptional performance and unparalleled convenience for modern households. This innovative appliance boasts a range of features that cater to the needs of discerning chefs and anyone who appreciates quality in their kitchen equipment.

One of the standout characteristics of the D8125INV is its sleek, integrated design. The built-in style allows it to blend seamlessly with your cabinetry, providing a streamlined look that enhances any kitchen decor. The ability to customize the front panel to match your cabinetry ensures that this appliance does not disrupt the aesthetic of your kitchen.

In terms of functionality, the D8125INV excels. It features a spacious capacity, offering ample room for cooking a variety of dishes simultaneously. The appliance is equipped with advanced cooking technologies, including a powerful convection system that ensures even heat distribution for perfectly cooked meals every time. This feature significantly reduces cooking times and enhances the quality of food.

The D8125INV also incorporates precision cooking with multiple cooking modes, including traditional bake, broil, and specialized modes like pizza and bread baking. These options cater to various culinary techniques and preferences, allowing users to experiment and explore different cooking styles with ease. The intuitive control panel provides easy access to these functions, ensuring that even novice cooks can achieve professional results.

Another remarkable aspect is the appliance's energy efficiency. With Bosch's commitment to sustainability, the D8125INV has been designed to consume minimal energy without compromising performance. This makes it an environmentally friendly choice for eco-conscious consumers.

Safety is also a priority with this model. It includes features such as a safety lock and an automatic shut-off function to prevent overheating and accidents in the kitchen, providing peace of mind while cooking.

Additionally, the easy-to-clean interior and removable racks make maintenance a breeze, allowing users to focus more on cooking and less on cleanup.

Overall, the Bosch Appliances D8125INV is a perfect blend of style, functionality, and efficiency, making it an ideal investment for those looking to elevate their culinary experience and kitchen design. With its innovative features and commitment to quality, this appliance stands out as a top choice for modern kitchens.