The RTX system combines the signal processing capabilities of the DigiOptic™ Image Processor with the high fidelity reproduction of the DLP™ technology Display by linking the two units via a fibre optic cable.
The DigiOptic™ Image Processor, which should be ideally located close to the signal sources, supports and processes a wide range of video signals, transmitting them to the display by means of a fibre optic link cable.
The large number of inputs available (2 Composite Video inputs, 2
The signal processing capabilities of the Image Processor ensure optimum reproduction of a broad range of input signals, from interlaced video to high definition and graphics.
Conversion of interlaced video signals to progressive signals by means of prestigious DCDi™ technology produces fluid, natural, images free of flicker and stairstepping artefacts.
Faithful reproduction of signals at higher resolutions (such as high definition video and graphics) occurs without loss of information or reduction of image sharpness thanks to the processor’s high pixel rate signal acquisition capabilities.
Adaptation of the input signal resolution to the Display resolution occurs without alterations of image quality, in accordance with an ample choice of aspect ratios, including several definable by the user.
All image adjustments can be performed with the remote control with the aid Ôf the On Screen Display; alternatively, the unit can be controlled by from a home automation system through the serial port.
The Display, with its elegant and original design, produces an image using the very latest Texas Instruments DLP™ technology (1280x720 pixel DMD™ panel with 12° technology), a proprietary
The two units are connected via a
Transmission occurs without interference or attenuation over distances of up to 500 m.
Moreover, the flexibility and small size of the cable allow the maximum freedom when installing the system in your home.
SIM2 carries out comprehensive functional testing in order to guarantee the maximum product quality. For this reason, when you start using the product lamp operating hours may already be at between 30 and 60.
In addition to the regular tests, the Quality Control department performs additional statistical tests at the time of shipment.
In this case the packing may show signs of having been opened, and the accumulated lamp operating hours may be slightly higher than the hours associ-
ated with the standard tests.