Vidikron 100 manual Connection

Page 13

QUICK CONNECTION AND SETUP GUIDE

Follow the steps below ensure proper installation of the Vision Model 100 projector.

NOTE: These steps should be performed by a qualified custom video installation specialist.

Step I

Connection:

1.Connect Power to the Projector.

2.Connect Video (Composite), S-Video to 1 or 2, Component 480i (RCA) input, HD signals to HD1 or HD2 (BNC),

DVI

3.Turn ON the system from the projector control panel and main power switch.

Step II

1.Press Menu to select Main window. Select the Service Menu, then Display Device, then the Lens Menu.

2.Adjust Lens shift, Zoom, and Focus for desired screen size and sharpness.

3.Press Menu to go back to the Service Menu, then select Display Device, then the menu for Installation to adjust Picture Orientation.

4.Select for projector mount configuration (Floor Front, Ceiling Front, Floor Rear, or Ceiling Rear)

Step III

Calibration and Setup:

1.Make sure you have Images on the screen from all connected sources.

Note: The system should be setup first by using S-Video or Component 480i (RCA input) preferably Component 480i first.

2.Select Component SD.

3.Using a test disc and select the Pluge pattern for Brightness and 10-step gray scale for Contrast

4.Select Calibration, press Enter and under ISF Night select Input Image.

5.Adjust for correct Brightness and Contrast.

6.Select 80 IRE from test disc.

7.Press Menu to select Main window. Enter the Calibration Menu, select Input Image and press Enter.

8.Select Contrast and press Enter.

Under Contrast you have Red, Green, and Blue selection.

9.Use the Up and Down arrow to select Green or Blue and press Enter. The cursor will blink from the selected color. Use the UP or Down arrow to adjust. Press Enter when done to store the number.

Note: Decrease the value to set for desired temperature.

10.Select 20 or 30 IRE window for low-end adjustment

11.Select Brightness and adjust RED, Green, or Blue for D6500. Note: Decrease the value to set for D6500.

12.Select color bar from test disc.

13.Select Calibration, press Enter and under ISF Night select Input Image and select Color and press Enter

14.Use the Blue Filter (required) and adjust for correct color setting.

15.For other NTSC sources, select Calibration, press Enter. Under ISF Night, select Input Image and adjust for correct Brightness, Contrast, Color, Tint, and sharpness.

Step IV

HD and DVI Setup:

1.For HD input and DVI, select Calibration press Enter and under ISF Night select Input Image for video adjustments.

2.Select Input Color for white balance adjustments.

12

Image 13
Contents G H T a M P D L P P R O J E C T O R Table of Contents » Contents of the package » The features you’ll enjoy includeIntroduction » OptionsProduct Disposal Information Declaration of Conformity Intellectual Property Rights Read Before Using the ProductLimited Warranty TWO Year Limited WarrantyVidikron Effective Warranty DateVideo 1 Input Projector Rear Panel InputsVideo 2 Input Power Button Main Power SwitchRS-232 Control Vacuum Florescent DisplayIR Output Indicator Remote Control DescriptionLight Button ENT Enter ButtonSource Selection Buttons Memory Settings ButtonsVideo Button Comp Component ButtonAnalog Inputs Quick Connection and Setup GuideConnection Step One HOW to Install or Remove the Projector LampStep Two Step ThreeStep Four Lens Shift Range Lens Option 4 Throw Distance 2.35 3.60 x Width of Screen » Example of Horizontal and Vertical Lens Shift » Opening Screen Menu Description and Navigation» Input Source » Aspect Ratio Menu Description and Navigation » Calibration For Service Only » ISF Presets» Service For Service Only » Input PositionProblem Possible Cause Solution Basic Troubleshooting TipsRS-232 Communications Command Parameter Value Stored? Description Min/max RS-232 CommandsRS-232 Commands Dimensions Specifications