AMX Wiring Devices to the AXC-232++, Card Edge Pinouts, Preparing captive wires, Using RS-232

Page 9

Installation and Wiring

Wiring Devices to the AXC-232++

Card Edge Pinouts

The table below lists the card edge pinouts and the function of each.

Card Edge Pinouts

 

Pin

Signal

Function

1

2

 

 

 

1

GND

Ground (RS-232)

3

 

 

 

2

RX

Receive data (RS-232)

4

 

 

 

5

3

TX

Transmit data (RS-232)

 

 

 

6

4

+12V

Power

7

 

 

 

5

RX -

Receive data (RS-422)

8

 

 

 

6

RX +

Receive data (RS-422)

9

GND

 

RX

RS-232

TX

 

+12 V RX

RX+ RS-422 TX-

TX+

GND

7

TX -

Transmit data (RS-422)

10

 

 

 

11

8

TX +

Transmit data (RS-422)

12

 

 

 

9

GND

Ground

13

 

 

 

 

 

 

14

10

CTS

Clear-to-send (hardware handshaking)

 

 

 

15

11

RTS

Ready-to-send (hardware handshaking)

16

 

 

 

12 - 16

Factory Use

 

 

 

CTS RTS

Hardware Handshaking

Preparing captive wires

To secure wires in a captive-wire connector:

1.Strip 1/4 inch off the wire insulation for all four wires.

2.Tin 2/3 of the exposed wire.

3.Insert each wire into the appropriate captive-wire connector, according to figures 9 through 12. Insert the wire up to the insulation.

4.Turn the captive screws clockwise to secure the fit in the connector.

If the device is using a separate power supply, do not connect the power wiring from the AXC-232++ to that device.

Using RS-232

When communicating via RS-232, connect the wiring as shown in FIG. 2.

AXC-

GND

GND

AXB- RX 232++

232++ TX

+12V

RX -

RX +

TX -

TX +

FIG. 2 RS-232 wiring

RX Device

TX

AXC-232++ RS-232/422/485 Interface Card

5

 

 

 

 

Image 9
Contents AXC-232++ Page Table of Contents AXC-232++ RS-232/422/485 Interface Card Specifications SpecificationsIntroduction Baud rates 300, 600, 1200 , 4800, 9600, 19200 Setting the Internal Jumpers Installation and WiringSetting jumper JP1 to terminate RS-422 input with 100 ohms Setting jumper JP2 to set the RS-422 port for RS-485 useRS-232/422 DIP Switch Settings Setting the RS-232/422 DIP SwitchPreparing captive wires Wiring Devices to the AXC-232++Using RS-232 Card Edge PinoutsUsing RS-485 Using RS-422Using Hardware Handshaking Installing the AXC-232++ in a CardFrameReplacing the Lithium Batteries Lithium battery and socketInstallation and Wiring SendCommands AXC-232++ SendCommandsProgramming Sendcommand AXC232,CTSPSH Sendcommand AXC232,CHARD-10Sendcommand AXC232,CTSPSHF Sendcommand AXC232,EOFFAxcess program characteristics SendString Escape Sequences SendString Escape SequencesAXC-232++ Program Statements AXC-232++ statementsXmodem Timing Commands Xmodem Timing CommandsAXlink Master Statements AXlink Master StatementsAxcess Master Mode Reserved ChannelsReserved Channels RevisionLast9/12/05