AMX AXC-232++ instruction manual Setting the RS-232/422 DIP Switch, RS-232/422 DIP Switch Settings

Page 8

Installation and Wiring

Setting the RS-232/422 DIP Switch

Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch (see FIG. 1). The AXC-232++ supports the following asynchronous data standards:

Stop bits 1 and 2

Data bits 7, 8, and 9

Parity None, Odd, Even, Mark, and Space

Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400.

57,600 is achieved by setting the DIP switch to 300 baud, and using the

BAUDMED’ Send_Command (see the Send_Commands section on page 9 for

details).

115,200 is achieved by setting the DIP switch to 300 baud, and using the

BAUDHIGH’ Send_Command (see the Send_Commands section on page 9 for details).

The table below shows the DIP switch numbers, functions, and their corresponding values.

RS-232/422 DIP Switch Settings

 

Switch

 

 

1

 

 

 

 

2

 

3

4

5

6

7

8

 

Function

 

 

Stop Bits

 

 

Data Bits

 

Parity

 

 

Baud Rates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

 

Off

 

 

 

 

Off

Off

Off

Off

Off

Off

Off

 

 

Value

 

 

2 bits

 

 

7 bits

 

Unused

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

 

 

 

On

On

Off

Off

On

Off

Off

 

 

 

 

 

1 bit

 

 

8 bits

 

Unused

 

 

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

Off

Off

On

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

Unused

 

 

1,200

 

 

 

RS232/422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

On

Off

On

On

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

Unused

 

 

2,400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

ON

Off

Off

On

Off

Off

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mark

 

 

4,800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

Off

On

On

Off

On

 

 

 

 

 

 

 

 

 

 

 

 

 

Even

 

 

9,600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

On

Off

On

On

 

 

 

 

 

 

 

 

 

 

 

 

 

Odd

 

 

19,200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

On

On

On

On

On

 

 

 

 

 

 

 

 

 

 

 

 

 

None

 

 

38,400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

AXC-232++ RS-232/422/485 Interface Card

 

 

 

Image 8
Contents AXC-232++ Page Table of Contents AXC-232++ RS-232/422/485 Interface Card Introduction SpecificationsSpecifications Baud rates 300, 600, 1200 , 4800, 9600, 19200 Installation and Wiring Setting the Internal JumpersSetting jumper JP1 to terminate RS-422 input with 100 ohms Setting jumper JP2 to set the RS-422 port for RS-485 useSetting the RS-232/422 DIP Switch RS-232/422 DIP Switch SettingsWiring Devices to the AXC-232++ Preparing captive wiresUsing RS-232 Card Edge PinoutsUsing RS-422 Using RS-485Using Hardware Handshaking Installing the AXC-232++ in a CardFrameLithium battery and socket Replacing the Lithium BatteriesInstallation and Wiring Programming SendCommandsAXC-232++ SendCommands Sendcommand AXC232,CHARD-10 Sendcommand AXC232,CTSPSHSendcommand AXC232,CTSPSHF Sendcommand AXC232,EOFFAxcess program characteristics SendString Escape Sequences SendString Escape SequencesAXC-232++ statements AXC-232++ Program StatementsXmodem Timing Commands Xmodem Timing CommandsAXlink Master Statements AXlink Master StatementsReserved Channels Axcess Master ModeReserved Channels RevisionLast9/12/05