AMX AXR-NWS Setting the Group Address DIP switch, Setting the Device Address on a touch panel

Page 9

Installation

Setting the GROUP ADDRESS DIP switch

You must remove the translucent faceplate on the front panel before you can access the DIP switches.

1.Determine the number of devices to control.

2.Allocate the device address range in sets of 16 (touch panel addresses can range from 0 - 255, but typically begin at 128).

3.Verify device address values are not already assigned to other devices.

4.Verify the device assignments fall within the range assigned for each Server (numerical range for any given AXR-NWS Group Address is 16).

5.Use the DIP switch values shown in Group Address DIP Switch Values table on page 4 to set the address of the first device for the group address range on the Server.

6.Use the DIP switch program, on AMX’s Control CD, to determine the DIP switch arrangement for a given value.

7.Enter the DIP switch value into the Device Number field, and the DIP switch on the right shows the corresponding switch arrangement.

8.Set the GROUP ADDRESS DIP switch on the AXR-NWS to begin at the value assigned to the first device.

Setting the Device Address on a touch panel

1.Press SETUP on the Main page of the touch panel.

2.Press PROTECTED SETUP on the Setup page to open the password keypad.

3.Enter 1988 (default password) in the keypad and press ENTER to open the Protected Setup page, shown in FIG. 3. If you enter a wrong number, press CLEAR and re-enter the number.

FIG. 3 ViewPoint protected setup page

4.Press DEVICE BASE to open the numeric keypad.

5.Set the base address value for the touch panel and press ENTER. The base address range is 1 - 255.

If four devices are used, and the base address is 128, the touch panel occupies device numbers 128 - 131.

AXR-NWS NetWave Server

5

 

 

 

 

Image 9
Contents AXR-NWS AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Specifications SpecificationsProduct Information Specifications Group ID InstallationGroup Address DIP Switch Values Setting the Group AddressSetting the Device Address on a touch panel Setting the Group Address DIP switchGroup ID DIP Switch Values Setting the Group IDSetting Group ID DIP switches Setting the Group ID on the touch panelPower guidelines Connecting to the ControllerWiring Guidelines Using AXlink for data and powerInstalling the Control System Using AXlink for data with an auxiliary power supplyPreparing captive wires NWA-EXT Specifications for the Optional NWA-EXTInstallation Replacing the Firmware Chip Firmware UpgradesFirmware Upgrades Installation AXR-NWS NetWave Server AMX,