D-Link DES-1008M manual Making Twisted-Pair Attachments

Page 29

DES-1008M User’s Guide

Making Twisted-Pair

Attachments

You can make twisted-pair attachments to the Switch by first installing DES-108TX modules. The system can be configured to have a maximum of eight switched twisted-pair ports. Each of these ports support N-Way or 100Mbps full-duplex force mode.

Depending on the node you are connecting to a twisted-pair port, you will need either a straight or crossover twisted-pair cable. For connection to a hub, you will need a crossover twisted-pair cable; for connection to other network devices such as servers and switches, you will need a crossover cable. A crossover cable is almost the same as an ordinary twisted-pair cable only that the pin configuration of a crossover cable is crossed over. Maximum cable length is 100 meters.

For information on cable pin configuration, see Appendix B, Cables and Connectors.

NOTE: You do not need to turn off the Switch when making network connections; just plug in the cables into the ports.

To make twisted-pair attachments to the Switch, follow these steps:

1.Depending on the number of twisted-pair attachments you want to create, install the appropriate number of DES-108TX modules into the Switch. Take note that each module provides two switched twisted-pair ports. For information on the installation procedure, see the Port Module Installation section of Chapter 3, Installation.

2.Obtain the cable needed in the connection; that is, straight cable for connection to a server, crossover twisted-pair for other devices. Ensure that this cable does not exceed 100 meters.

Making Network Connections

19

Image 29
Contents DES-1008M Flex-Media Ethernet Switch User’s Guide Wichtige Sicherheitshinweise Limited Warranty Link Offices for Registration and Warranty Service Limitation of Warranties Page Trademarks Page Table of Contents LIDE- in P ORT M Odules Terms About this GuideAbout this Guide Bandwidth Boost Eight User-Configurable PortsProduct Overview Comprehensive LED Indicators Easy InstallationPowerful Performance Unpacking Unpacking Component IdentificationIdentifying External Components Indicator PanelSlots 1 to Power IndicatorFDX/Col Indicator 100M IndicatorLink/Act Indicator Fuse Case AC Power ConnectorSystem Fan Power Switch Site Installation InstallationRack Mounting Installation Connecting Power Port Module InstallationReplacing the Fuse Damaged one. Doing so may cause serious damage to the Switch Network Design Notes Making Network ConnectionsCable Limitations Making Twisted-Pair Attachments Making Thin Coaxial Attachments Making Network Connections DES-1008M User’s Guide Making Fiber Attachments DES-1008M User’s Guide 100BASE-FX Technical SpecificationsNumber of Ports Safety 10/100BASE-T Twisted-Pair Cable Cables Connectors10BASE2 Thin Coaxial Cable 10BASE-FL/100BASE-FX Fiber- Optic Cable DES-108TX SLIDE-IN Port ModulesDES-108C DES-108FL DES-1008M User’s Guide Index Slide-In Port Modules Offices Taiwan Link Taiwan Registration Card