Altinex manual None, Manual Loop Control, MX2406RM Loop, Loop Control with RS-232 Command

Page 11

SWITCHERS

accommodate this need. The pin-outs for this adapter are as follows:

9 pin “D”

Description

9 pin “D”

Input

Male

 

Female

 

 

 

 

 

7

1.2K

1

1

7

3.3K

2

2

7

6.8K

3

3

7

12K

4

4

7

22K

5

5

7

51K

6

6

7

0 short

7

NONE

5

Ground

9

 

The following voltages apply for selecting the required channel:

Input number

min. (V)

nom. (V)

max. (V)

 

 

 

 

1

0.35

0.55

0.75

2

1.07

1.27

1.47

3

1.80

2.00

2.20

4

2.52

2.72

2.92

5

3.25

3.45

3.65

6

3.97

4.17

4.37

These voltage levels can be set using analog outputs from different control systems or spare dimmer control outputs.

7.5 MANUAL LOOP CONTROL

Loop control is used when multiple units of the MX2406RM are connected to form a single switcher. When the input channel button is pressed the loop control pin is internally grounded and the MX2406RM Switcher selects INPUT 4 as the default input.

In this configuration, loop control pin 6 on the 9 pin D connector is connected to the same pin on all switchers.

MX2406RM LOOP

MX2406RM LOOP

6

6

5

5

MX2406RM 9-pin “D” Loop

The loop control pin has an internal 100k resistor to +5volts. This limits the number of switchers that can be looped to a maximum of 10 switchers that can be daisy chained together using this method.

More specifically, the output of one switcher is connected to INPUT 6 of the next switcher. Once loop control is enabled these switchers will automatically switch video signals to the output of the second switcher through INPUT 6. Keep in mind that you are always going to have one less input than the total number of inputs available on all switchers. The figure above is for an 11-in 1-out switcher.

7.6 LOOP CONTROL WITH RS-232 COMMAND

When multiple MX2406RM units are connected to form a single switcher and RS-232 commands are used to control these units, please connect units according to following diagram.

If you want to make 11 by 1 switcher using two 6 by 1 switchers, the following commands need to be used to control these switchers:

Input 1 through Input 6

[OUT01]

10

Image 11
Contents MX2406RM Table of Contents General Precautions / Safety WarningsInstallation CleaningTechnical Specifications About Your SwitcherDescription of MX2406RM Select Input Auto Switch Mode ButtonReset Button Power UP Default SETAnalog Output Application DiagramPower Supply BI-DIRECTIONAL Switching CONGRATULATIONS! YOU are Done Installing Your Switcher Operation Stand by RS-232 ProtocolRset VernMX2406RM 9-pin D MASTER-SLAVE ConfigurationMaster-Slave Analog Switch Voltage Connection Contact Closure ONE Wire Analog ControlMX2406RM Loop Loop Control with RS-232 CommandNone Manual Loop ControlHigh Resolution VGA Cable AccessoriesMX2406RM Frequently Asked QuestionsTroubleshooting Guide ResetToll Free 1-800-ALTINEX Limited WarrantyAltinex Policy Return Policy