Example:

If there are two MT104-102cards in slot 6 and 7 of unit 3: To enable input 1 of card 6 and input 3 of card 7 simultaneously, use the following commands:

[ON1C6U3P]

[ON3C7U3P] [SW]

If "F" is included use the [ONmCnUiPF] command or the [ONmCnUiFP] command.

[ON…F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero.

Example:

[ON1C2U3F]: if path is not set

[ON1C2U3PF]: if path is set

4. [OFF]

This command disables one or all inputs of a single card or a group of cards.

[OFFmCnUiS]: for a single card

This command disables input “m” or all inputs. [OFFC5CnUi]: Turns OFF all inputs of the MT104- 102 card.

m = Input number (m = 1 to 6)

Cn = Card ID number (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106)

Ui = Unit ID number (i = 0 to 9) S = saves command to memory

Example:

If card 5 of unit 3 has input 1 ON, the following commands can be used to turn OFF the input.

1)[OFF1C5U3]: Turns OFF only input 1.

2)[OFFC5U3]: All inputs are OFF.

[OFFmGkUiS]: for a group of cards

This command disables input "m" for each card in group "k" of unit "i".

m = card input (m = # from 1-6)

Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9)

S = saves command to memory

Example:

1.[OFF1G1U1]: Turns OFF input 1 for each card in group 1 of unit 1.

2.[OFFG1U1]: Turns OFF all inputs for each card in group 1 of unit 1.

[OFF…P]: sets path

This command will set the path for the output, but it is not active until the switch command is executed ([SW]). Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded.

Command Format: [OFFmCnUiP] m = input number (m = 1 to 6)

Cn = card ID no. (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106) Ui = unit number (i = # from 0-9)

P = path

Example:

If there are two MT104-102cards in slot 6 and 7 of unit 3: To enable input 1 of card 6 and input 3 of card 7 simultaneously, use the following commands:

[OFF1C6U3P]

[OFF3C7U3P] [SW]

If "F" is included use the [OFFmCnUiPF] command or the [OFFmCnUiFP] command.

[OFF…F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero.

Example:

[OFF1C2U3F]: if path is not set

[OFF1C2U3PF]: if path is set

5. [SW]

The switch command immediately connects inputs and outputs, which were previously set with the path command on this card and all other cards in the MT100-100.

Example:

[ON1C6U3P]

[ON3C7U3P]

8

Image 9
Contents MT104-102 Table of Contents Installation Precautions / Safety WarningsCleaning GeneralAbout Your MT104-102 Technical SpecificationsMT104-102 MechanicalApplication Diagram Product Description Application DiagramApplication Diagram 2 Internal View of the MT104-102 Installing Your MT104-102 Description of CommandsOperation Error Codes OFF ∙ ON…F feedback∙ OFFmCnUiS for a single card ∙ OFFmGkUiS for a group of cardsCLR SIGCiHelp Summary of Commands Troubleshooting GuideLED is not LIT LED is Blinking REDAltinex Policy Limited WarrantyNo Display Return Policy