Allied Telesis AT-8000GS, AT-S95 New Features, Operational Notes, Resolved Issues, Known Issues

Page 2
What’s New in Version 2.0.0.27

AT-S95 Version 2.0.0.27 Software Release Notes

The AT-8000GS/24, AT-8000GS/24POE, and AT-8000GS/48 switches can be combined together in a six-unit high stack.

What’s New in Version 2.0.0.27

New Features

None

Operational Notes

The default setting of the MODE LED is FDX (instead of ACT) when the switch is first turned on for Version 2.0.0.26 management software.

Resolved Issues

Fatal error reporting task LPCL, when users perform 802.1x authentication (CQ 134428 ATI293)

Guest VLAN timeout doesn’t work even if port is changing its state from up/down (CQ134167 ATI295)

DNS behavior is inconsistent (CQ129822 ATI285)

Daylight Saving Time setting does not function properly in the southern hemisphere (CQ 138179 ATI 308)

Adding the ability to change IP address remotely in one step. (CQ 141261 ATI 313)

Known Issues

The following known issues are present in the current release of the AT-S95 software:

Default VLAN - Disabling the default VLAN is not allowed in this release, according to the device specifications. As a part of backward compatibility support, upgrading a device which has the default VLAN disabled on it to latest version will succeed. Relevant errors for compatibility of configuration are displayed.

Compatibility - To allow proper support of backward and forward compatibility switching between the old and new images using an existing configuration file (created on an older version) should be done by 'reload'.

Port Mirroring - Target port that is configured to 802.1x Auto should not send EAP packets. This is a minor issue as it does not undermine functionality or performance.

QoS: Egress Tagged Port send frames with default user priority 1 instead 0.

Stack: Master and backup are 24 ports non PoE, slave unit 3 is 48 ports. When reloading unit 2 the master reboots rarely.

DHCP Option 82: the device doesn’t recognize option 82 fields that refer to the device itself (to the internal interface). Instead of getting an IP address, the device removes the option 82 field (which is actually correct) and then it transmits the traffic to the trusted ports.

MAC Support: Max 1K MAC Addresses can be configured as delete-on-timeout/reset.

Statistics: Received packets are not increased in the RMON statistics.

PN 613-001778 Rev A

2

Allied Telesis, Inc.

Image 2
Contents Supported Platforms AT-S95 Version AT-8000GS Switch Software Release NotesKnown Issues New FeaturesResolved Issues Operational Notes Security port lock Port security mechanism is not triggered for MAC violation if MAC is learned on another locked port as a secured MAC address Upgrading the AT-S95 Bootloader Code and Software with the CLI Upgrade Procedure6. Reboot the device with the following command The File System tab is displayed. See Figure 2 on page 8. Click OK Product Documentation History of Resolved IssuesWhere to Find Product Information and Management Software Updates History of Previous VersionsCLI Command History of New FeaturesTable 1 New Command Description DescriptionContacting Allied Telesis Contacting Allied Telesis