52 | AR700 Series Router |
| Figure 21: Pin wiring for terminal cable to connect asyn port on AR725, AR745 or |
|
| RJ45 |
| DB25 Female | ||
(to switch or router) |
| (to terminal) | |||
← (RXD) | 5 |
| 1 | Not connected | |
| 2 |
| |||
|
| ||||
→ (TXD) | 6 |
| 3 |
| |
|
| ||||
← (CTS) | 7 |
| 4 |
| |
|
| ||||
→ (RTS) |
| 8 |
| 5 | Not connected |
|
| ||||
→ (GND) | 4 |
| 6 | ||
| 7 |
| |||
|
| ||||
← (DTR) | 3 |
| 8 |
| |
|
| ||||
← (DCD) | 2 |
| 20 |
| |
|
| ||||
← (RING) | 1 |
| 22 |
| |
|
| ||||
Notes: | Other pins are not connected. |
|
| ||
(1) |
|
| |||
(2) | → Output from switch or router; ← Input to switch or router. | ||||
(3) | Cable version 1.0. |
|
|
TERMINAL
Figure 22: Pin wiring for terminal cable to connect asyn port on AR750S, AR750S-DP or
AR770S to DB25 female (terminal) port
| |
(to router) | |
← (RXD) | 6 |
→ (TXD) | 3 |
← (CTS) | 8 |
→ (RTS) | 1 |
→ (GND) | 4 |
→ (GND) | 5 |
→ (DTR) | 2 |
← (DCD) | 7 |
DB25 Female (to terminal)
1Not connected
6Not connected
20
22Not connected
Notes:
(1)Other pins are not connected.
(2)→ Output from switch or router; ← Input to switch or router.
(3)Cable version 1.0.