Allied Telesis 8624T/2M Install SFPs, Check the supply voltage and the switch’s rated voltage

Page 9

Installation & Safety Guide

9

Mount the switch in the rack using standard screws (these are not provided).

7.Install SFPs

For the AT-8648T/2SP, you may also need an optional SFP (Small Form- factor Pluggable module).

Do not look into the optical ports of SFP cables or transceivers. Invisible laser radiation may be emitted from disconnected fibres or connectors.

The SFP transceivers must be inserted the right way into the SFP 49 or SPF 50 slots. See the figure below.

Slide the transceiver into the SFP socket, and firmly press it until it engages. To remove it, first release it by gently pulling the release lever, and then pull it out of the socket. Never force a transceiver into or out of a socket.

When an SFP is installed into one of the two SFP ports, that SFP port takes precedence over its corresponding 10/100/1000T port. When the SFP is removed, the 10/100/1000T port is once again active.

8.Check the supply voltage and the switch’s rated voltage

AT-8600 Series switches are fitted with a universal main power supply that will function over the range 100–240 VAC and 50–60 Hz.

The specific power supply requirements for a particular model are clearly displayed on the rear or underside of the switch. If the supply is outside the accepted range for the switch, the switch may not operate or damage to the switch may result.

Image 9
Contents Installation and Safety Guide AT-8600 Series Switch Installation & Safety Guide Electrical Safety and Emission Compliance StatementElektrische Sicherheit Electrical SafetyElektrisk sikkerhed Elektrische veiligheidTable of Contents Models Covered By This Guide Package ContentsSelecting a Site Unpack the switch How to Install the SwitchInstall expansion modules optional Choose a suitable operating locationCheck the supply voltage and the switch’s rated voltage Install SFPsConnect the data cables Apply AC power to the switchConnect a terminal or PC to the Terminal Port ASYN0 How to Configure the SwitchSet the communication parameters LogConnect the PC to the switch Change password and display helpAccess the switch’s command line interface Select a PC to use and identify its subnetEnable IP. enable ip State Description System LEDsLink OFF Mode LEDs Link and Mode LEDs for the AT-8624PoE switchPoE Mode State Description StatusBetween the port and the end SFP and 10/100/1000Base-T LEDs for the AT-8648T/2SP switch Documentation and Tools CD-ROM Safety Electrical NoticesElectrical AC Mains Circuit Overloading Sicherheit Achtung Gefährliche SpannungGefahr Durch Blitzschlag Vorsicht NetzsicherungVorsicht Rahmeneinbau Fare Under Uvejr SikkerhedLynaktivitet Elektrisk Klasse 1-UDSTYR ELEKTRISK-OVERBELASTNING AF SpændingskredsløbetVeiligheid Gevaar Voor BlikseminslagElektrische Toestellen VAN Klasse Sécurité Équipement DE Classe 1 Électrique TurvallisuusSalamaniskuvaara Sähköön Liittyviä Huomautuksia Varoitus SähköiskuvaaraSähkö Tyyppiluokan 1 Laitteet SÄHKÖ-VAIHTORVIRTASÄHKÖPIIRIN YlikuormitusPericolo DI Fulmini Norme di SicurezzaPrecipitazioni Temporalesche Elettricità Dispositivi DI ClasseElektrisitet SikkerhetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrSegurança Elektrisk Overbelastning PÅ AC HovedkretsløpPerigo DE Choque Causado POR Raio Elétrico Equipamentos do Tipo Classe SeguridadAvisos Electricos Advertencia Peligro DE Electrochoque Peligro DE RayosElectrico Equipo DEL Tipo Clase Tillkännagivanden Beträffande Elektricitetsrisk SäkerhetFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningAT-8600 Series Switch We Allied Telesis Labs Limited EC Declaration of Conformity