Instant EtherFast II Series
How to Install An Add-On Module
Follow these steps to install the
1.Power off the hub and remove the AC power cord from the hub.
2.Remove all
3.Using a Phillips screw driver, remove the screws holding the small cover panel on the back of the hub. The size of the panel is about 8.1cm by 3.5cm (3.1" x 1.4"). You will need the screws to secure the
4.Ground yourself properly and remove the
5.Hold the module so the chips and the components on the
6.The
7.Secure the module in place with the two screws.
8.If used on a rack, mount the hub back on the rack. Reconnect the
9.Connect your Fiber cable or
10/100 Hubs
Fiber Optic Modules
Two different Fiber Optic modules are available for the
EF2HSC: 100BaseFX
EF2HST: 100BaseFX
Each Fiber port has two connectors, a transmit (TX) and a receive (RX). To connect two modules together, you must run a
Each Distance Extender Modules has a switch on the back for Full Duplex or Half Duplex. The switch must be set to Half Duplex at all times, when con- necting to another Distance Extender or a Transceiver module. The Link LED will light up when there is a connection made, and the Activity (ACT) LED will flicker while data is being transmitted or received.
Note: The duplexing switch (located on the back of the hub) should be set in Half Duplex mode. The 10/100 Hubs do not function in full duplex mode.
A maximum of 2 Transceivers can be connected together in one segment. When two hubs are connected via Transceivers together, the same rule of cas- cading two 100Mb hubs applies to them. To cascade another hub to these two hubs (using
The Distance Extender is a switched port. This means another 100Mb hub can be cascaded (with