(English)
LED
STATUS LED
The STATUS LED goes on green when the Switch Module operates normally. When the LED is lit or flashing in amber, it indicates that the Switch Module has failed. The following table lists indications of the STATUS LED, descriptions, and actions to take. If an error occurs, contact your service representative.
STATUS LED | Description | Action |
On (Green) | The Switch Module is operating | - |
| normally. |
|
|
|
|
Off | The power is turned off. | Turn on the power. |
|
|
|
Flash (Amber) | The following errors have been | When installed in the Blade Enclosure (6U), an |
| detected. | error message is displayed on the |
| - Abnormal temperature | SIGMABLADE monitor. |
| - Processor error or other | Refer to the User’s Guide of the EM Card. |
| components error |
|
| Switch Module interface | When installed in the Blade Enclosure (6U), |
| mismatch | “SWMn Ifmiss Alm” (n: slot number) is displayed |
|
| on the SIGMABLADE monitor. See page 28 |
|
| “Connection with CPU Blade”, and make sure |
|
| the location of the Mezzanine Card in the CPU |
|
| Blade and the Switch Module. |
|
| Refer to the User’s Guide of the Blade |
|
| Enclosure. |
ID LED
The ID LED is intended to identify a specific Switch Module in the Blade Enclosure when more than one Switch Modules are installed. Making this LED being lit can help the maintenance work to identify the faulty device. When the recognized command is received from the management software such as NEC ESMPRO/Server Manager, the LED goes on or flashes in blue.
ID LED | Description |
On or Flash in blue | Management software has specified the Switch Module. |
Off | Other than the above |
25