Fault detection and alarm notification
•Power failure: This operates only when you have installed the redundant power supply
•Fan failure: If any of the three cooling fans fails, the dedicated LED changes color from green to red, and an audio alarm also sounds. The dedicated LED remains red for the failed fan until it is fixed. The fan assembly can be
•High temperature: If the chassis interior temperature exceeds 65o C (149o F) (standard setting), the LED changes color from green to red, and an audio alarm also sounds. The LED remains red until the temperature drops below 63o C.
•Temperature select: The temperature threshold can be adjusted to one of four readings, by setting
the switch on the alarm board: 65o C (default setting), 55o C, 70o C and 75o C.
•Audible alarm: A buzzer on board is activated (continous beep) as soon as a malfunction is detected, and sounds until the alarm reset button is pressed. The alarm reset button is on the front panel. However, the alarm indicator will stay red until the fault condition is resolved.
•