Advantech SPC-530 user manual Fault detection and alarm notification

Page 6

Fault detection and alarm notification

Power failure: This operates only when you have installed the redundant power supply (RPS-400ATX). If either of the two power modules fails, the dedicated LED (PWR) changes color from green to red, and an audio alarm also sounds. The dedicated LED remains red for the failed power module until it is fixed.

Fan failure: If any of the three cooling fans fails, the dedicated LED changes color from green to red, and an audio alarm also sounds. The dedicated LED remains red for the failed fan until it is fixed. The fan assembly can be hot-swapped if any fan fails.

High temperature: If the chassis interior temperature exceeds 65o C (149o F) (standard setting), the LED changes color from green to red, and an audio alarm also sounds. The LED remains red until the temperature drops below 63o C.

Temperature select: The temperature threshold can be adjusted to one of four readings, by setting

the switch on the alarm board: 65o C (default setting), 55o C, 70o C and 75o C.

Audible alarm: A buzzer on board is activated (continous beep) as soon as a malfunction is detected, and sounds until the alarm reset button is pressed. The alarm reset button is on the front panel. However, the alarm indicator will stay red until the fault condition is resolved.

Self-test:Press the alarm reset button for 8 seconds, and the alarm board will self-test automatically for all functions. The alarm board can also monitor the temperature's sensor IC. If the sensor has failed, or there is no connection, the buzzer will sound a " Beep x Beep x ..." alarm.

Controls for the system

The SPC-530 series' front panel provides one soft switch and one system reset button to re-boot the PC system. See the following figure:

SPC-530 User's Manual

3

Image 6
Contents SPC-530 Copyright Notice Acknowledgments Contents Specifications General Information IntroductionModel list Passive backplane options for SPC-530BP / SPC-530BP-U2C Fault detection and alarm notification Dimensions System Setup Removing the coverRemoving the handles Cooling fansInstalling the disk drives Temperature settingInstalling the power supply unit Resistor Signals Appendix a Backplanes OptionalPage Page Appendix B Exploded Diagrams SPC-530BP Appendix C Safety Instructions Do not Cover the Openings