RuggedCom RX5000 manual Technical Specifications, Power Supply Specifications

Page 29

4. Technical Specifications

4. Technical Specifications

4.1. Power Supply Specifications

Power Supply Type

Input Range

 

Internal Fuse Rating

Max. Power

Min

Max

Consumptiona

HI (125/250 VDC)b

88 VDC

300 VDC

6.3A, 250V(T)c

84 Wd

HI (110/230 VAC)b

85 VAC

264 VAC

6.3A, 250V(T)c

84 Wd

aPower consumption varies based on configuration, i.e. the number and type of ports. Each 10/100Base-TX port consumes roughly 1W less than a fiber optic port.

bThe “HI” power supply is the same power supply for both AC and DC.

c(T) denotes time-delay fuse. Internal fuse is not user-replaceable.

dRating at 85°C ambient temperature at worst-case load.

Table 4.1. Power Supply Specifications

4.2. Critical Alarm Relay Specifications

Parameter

Value

(Resistive Load)

Max Switching Voltage

250

VAC, 125 VDC

 

 

Rated Switching Current

2A@250VAC, 2A@30VDC

 

 

 

Table 4.2. Critical Alarm Relay Specifications

4.3. Copper Ethernet Port Specifications

The RX5000 can be ordered with several different modules which contain 10/100Tx or 10/100/1000Tx Ethernet ports. All copper Ethernet ports have the following specifications:

Parameter

Specification

Notes

Speed

10/100 or 10/100/1000 Mbps

Auto-negotiating

 

 

 

Duplex

FDX / HDX

Auto-negotiating

 

 

 

Cable-Type

> Category 5

Shielded/Unshielded

 

 

 

Wiring Standard

TIA/EIA T568A/B

Auto-Crossover, Auto-Polarity

 

 

 

Max Distance

100 m

 

 

 

 

Connector

RJ45

 

 

 

 

Isolation

1.5kV

RMS 1-minute

 

 

 

Table 4.3. Copper Ethernet Port Specifications

RuggedCom® RuggedBackbone™

29

RX5000 Installation Guide Rev106

Image 29
Contents RuggedBackbone RX5000 All Rights Reserved Warranty Contacting RuggedComDisclaimer Of Liability Registered TrademarksTable of Contents List of Figures List of Tables FCC Statement And Cautions Functional Overview Feature HighlightsProduct Overview Netconf RuggedBackbone Modules Installing a Module In The ChassisControl Module Control ModuleSwitch Switch ModuleTX01 Line ModulesPower Supply Module Power ModuleRack Mounting InstallationMounting Rack Front Mounting Rack Front Mount Top View Rack Front Mounting with Front-Mounted Power Supplies Rack Front Mount with Front-Mount Power Supplies Top View Rack Rear Mounting 10. Rack Rear Mount Top View 11. Panel Mount Side View Panel MountingPin Function Power Supply Wiring And GroundingAC Power Supply Wiring DC Power Supply Wiring15. AC Power Separate Earth Connection 16. Critical Alarm Relay Connection Critical Alarm Relay17. Serial Console Port Serial Console Ports1. RJ45 Twisted-Pair Copper Ports Copper Ethernet PortsGigabit Ethernet 1000Base-TX Cabling Recommendations RJ45 Pin 10/100Base-Tx 10/100/1000Base-TxTransient Suppression Fiber Ethernet PortsPower Supply Specifications Technical SpecificationsCritical Alarm Relay Specifications Copper Ethernet Port SpecificationsGigabit Ethernet 1Gbps Optical Specifications Fiber Ethernet Port SpecificationsFast Ethernet 100Mbps Optical Specifications Operating Environment Mechanical SpecificationsParameter Range Comments Parameter Value CommentsTest Description Test Levels Severity EMI And Environmental Type TestsTest Test Description Test LevelsAgency Standards Comments Agency ApprovalsRuggedCom Inc Warranty