RuggedCom RX5000 manual RuggedBackbone Modules, Installing a Module In The Chassis

Page 9

2. RuggedBackbone™ Modules

2. RuggedBackbone™ Modules

The RX5000 chassis comprises ten slots, each one of which is designed to accommodate a particular module. Figure 2.1 shows the rear panel view of the RX5000. The slot name at each position (“PM1”, “L1”, etc.) denotes the type of module that may be installed at that position in the chassis.

Figure 2.1. Chassis Slot Assignment

The slot name markings in the diagram above represent the following RuggedBackbone™ modules:

CM

The Control Module is the central processing unit of the system. Refer to Section 2.2: Control Module for detail.

SM

The Switch Module contains the chassis-wide Ethernet switch fabric that interconnects Ethernet ports on all installed line modules. Refer to Section 2.3: Switch Module for detail.

L1..L6

One or more Line Module cards may be installed - refer to Section 2.4: Line Modules for detail.

PM1, PM2

Dual, redundant, power supply modules may be installed - refer to Section 2.5: Power Module for detail.

All supported modules are built to the RuggedRated™ specifications of the RuggedBackbone™ RX5000. Each of the module types is detailed in the following sections.

2.1. Installing A Module In The Chassis

In order to install a module into the RuggedBackbone™ chassis, align the module guide ribs with the channels on the chassis, and push the module in as far as it will go. There is a detent position that must be pushed through to properly seat the connectors - this is the added resistance from the grounding springs. When properly seated, the module flange will rest on the main chassis frame. Tighten the thumbscrews using finger strength only.

RuggedCom® RuggedBackbone™

9

RX5000 Installation Guide Rev106

Image 9 Contents
RuggedBackbone RX5000 All Rights Reserved Warranty Contacting RuggedComDisclaimer Of Liability Registered TrademarksTable of Contents List of Figures List of Tables FCC Statement And Cautions Feature Highlights Product OverviewFunctional Overview Netconf RuggedBackbone Modules Installing a Module In The ChassisControl Module Control ModuleSwitch Switch ModuleTX01 Line ModulesPower Supply Module Power ModuleInstallation MountingRack Mounting Rack Front Mounting Rack Front Mount Top View Rack Front Mounting with Front-Mounted Power Supplies Rack Front Mount with Front-Mount Power Supplies Top View Rack Rear Mounting 10. Rack Rear Mount Top View 11. Panel Mount Side View Panel MountingPin Function Power Supply Wiring And GroundingAC Power Supply Wiring DC Power Supply Wiring15. AC Power Separate Earth Connection 16. Critical Alarm Relay Connection Critical Alarm Relay17. Serial Console Port Serial Console Ports1. RJ45 Twisted-Pair Copper Ports Copper Ethernet PortsGigabit Ethernet 1000Base-TX Cabling Recommendations RJ45 Pin 10/100Base-Tx 10/100/1000Base-TxTransient Suppression Fiber Ethernet PortsPower Supply Specifications Technical SpecificationsCritical Alarm Relay Specifications Copper Ethernet Port SpecificationsFiber Ethernet Port Specifications Fast Ethernet 100Mbps Optical SpecificationsGigabit Ethernet 1Gbps Optical Specifications Operating Environment Mechanical SpecificationsParameter Range Comments Parameter Value CommentsTest Description Test Levels Severity EMI And Environmental Type TestsTest Test Description Test LevelsAgency Standards Comments Agency ApprovalsRuggedCom Inc Warranty