RuggedCom RX1510 manual EMI And Environmental Type Tests, Test Description Test Levels Severity

Page 42

5. EMI And Environmental Type Tests

5. EMI And Environmental Type Tests

Test

Description

Test Levels

Severity

Levels

 

 

 

 

IEC 61000-4-2

ESD

Enclosure Contact

+/- 8 kV

4

 

 

 

Enclosure Air

+/- 15 kV

4

 

 

 

 

 

 

 

IEC 61000-4-3

Radiated RFI

Enclosure Ports

20 V/m

Notea

 

 

Signal ports

+/- 4kV @ 2.5kHz

Notea

IEC 61000-4-4

Burst (Fast Transient)

D.C. Power ports

+/- 4kV

4

 

 

 

A.C. Power ports

+/- 4kV

4

 

 

 

 

 

 

 

 

 

Earth ground ports

+/- 4kV

4

 

 

 

 

 

 

 

Signal ports

+/- 4kV line-to-earth,

4

 

 

+/- 2kV line-to-line

 

 

 

 

 

 

 

 

 

IEC 61000-4-5

Surge

D.C. Power ports

+/- 2kV line-to-earth,

3

+/- 1kV line-to-line

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

+/- 4kV line-to-earth,

4

 

 

+/- 2kV line-to-line

 

 

 

 

 

 

 

 

 

 

 

Signal ports

10V

3

 

 

 

 

 

IEC 61000-4-6

Induced (Conducted) RFI

D.C Power ports

10V

3

 

 

 

A.C. Power ports

10V

3

 

 

 

 

 

 

 

 

 

Earth ground ports

10V

3

 

 

 

 

 

 

 

 

40 A/m, continuous,

Notea

IEC 61000-4-8

Magnetic Field

Enclosure Ports

1000 A/m for 1 s

 

 

 

 

1000 A/m for 1 s

5

 

 

 

 

 

 

 

D.C. Power ports

30% for 0.1s, 60% for

N/A

 

 

0.1s, 100% for 0.05s

IEC 61000-4-29

Voltage Dips & Interrupts

 

 

 

 

 

A.C. Power ports

30% for 1 period,

N/A

 

 

 

 

60% for 50 periods

 

 

 

 

 

 

 

 

 

IEC 61000-4-11

Voltage Dips & Interrupts

A.C. Power ports

100% for 5 periods,

N/A

100% for 50 periods

 

 

 

 

 

 

 

 

 

 

 

Signal ports

2.5kV common, 1kV

3

 

 

diff. mode@1MHz

 

 

 

 

 

 

 

 

 

IEC 61000-4-12

Damped Oscillatory

D.C. Power ports

2.5kV common, 1kV

3

diff. mode@1MHz

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

2.5kV common, 1kV

3

 

 

diff. mode@1MHz

 

 

 

 

 

 

 

 

 

IEC 61000-4-16

Mains Frequency Voltage

Signal ports

30V Continuous, 300V for 1s

4

 

 

 

D.C. Power ports

30V Continuous, 300V for 1s

4

 

 

 

 

 

 

 

IEC 61000-4-17

Ripple on D.C.

D.C. Power ports

10%

3

Power Supply

 

 

 

 

 

 

 

 

 

 

 

Signal ports

2kVAC (Fail-Safe Relay output)

N/A

 

 

 

 

 

IEC 60255-5

Dielectric Strength

D.C. Power ports

1.5kVDC

N/A

 

 

 

 

 

 

 

A.C. Power ports

2kVAC

N/A

 

 

 

 

 

 

 

Signal ports

5kV (Fail-Safe Relay output)

N/A

 

 

 

 

 

IEC 60255-5

H.V. Impulse

D.C. Power ports

5kV

N/A

 

 

 

 

 

 

 

A.C. Power ports

5kV

N/A

aRuggedCom-specified severity levels

Table 5.1. IEC 61850-3 EMI Type Tests

RuggedCom® RuggedBackbone™

42

RX1510 Installation Guide Rev 104

Image 42
Contents RuggedBackbone RX1510 Disclaimer Of Liability Warranty Contacting RuggedComAll Rights Reserved Registered TrademarksTable of Contents Page List of Figures Page List of Tables FCC Statement And Cautions Feature Highlights Product OverviewFunctional Overview WAN RuggedBackbone Modules LM1 through LM4Purpose Description Green = OK LM 1 through Front PanelModule Status LEDs Orange = Warning alertLine Modules LM Ethernet CopperEthernet Fiber Serial SFP ModularWAN Cellular ModemDDS Digital Data Services APE Appplication Processing EnginePower Supply 27. Pluggable terminal block power module HIP module shownInstallation Mounting1. RX1510Dimensions DIN Rail Mounting Side ViewRX1510Dimensions Top View Power Supply Wiring and Grounding Connectors for HI and HIP Power ModulesConnectors for 24, 24P, 48, and 48P Power Modules AC Power Supply Wiring Chassis Ground ConnectionDC Power Supply Wiring Examples AC and DC Power Supply Wiring ExampleCritical Alarm Wiring 15. Critical Alarm Relay ConnectorWAN Ports RJ45 RJ45 Pin Signal FunctionSerial Console Port T1/E1 pinout1. RJ45 Twisted-Pair Copper Ports WAN Ports BNCCopper Ethernet Ports Gigabit Ethernet 1000Base-TX Cabling RecommendationsTransient Suppression Cabling Category 1000Base Required ActionDDS Ports RJ45 Pin RS232 Mode RS485 Mode RS422 ModeSerial Ports RJ45 RJ45 Pin DescriptionRx LED Color Status SFP Optics Installation, removal, and precautionsDDS Rx and Tx LED Indications Tx LED Color StatusModule Insertion SFP SFP Module RemovalFiber Ethernet Ports 25. SFP module removalCellular Modems Module Order Code DescriptionInstalling SIM Cards for GSM, EDGE, HSPA+ Cellular Modems GSM, EDGE, HSPA+ Cellular Modem CardPage APE Overview Feature DescriptionAPE Application Processing Engine Supported Operating SystemsSecondary Network Interface Placing the APE in a VlanInstalling an Operating System Procedure 3.1. To install an operating systemLED Indicators APE BiosResetting the Module LED Color and StateFAQs Critical Alarm Relay Specifications Technical SpecificationsPower Supply Specifications Copper Ethernet Port SpecificationsCable Tx λ typ Tx min Tx max Distance Power Fiber Ethernet Port SpecificationsFast Ethernet 100Mbps Optical Specifications OrderMechanical Specifications Gigabit Ethernet 1Gbps Optical SpecificationsOperating Environment EMI And Environmental Type Tests Test Description Test Levels SeverityIeee 1613 C37.90.x EMI Immunity Type Testsa Test Description Test LevelsAgency Approvals Agency Standards CommentsWarranty RuggedCom Inc