3Com C17304, 3C17300, C17302 Command Line, Interface Management, CLI Management via, Console Port

Page 47

Setting Up Command Line Interface Management 47

Figure 18 SNMP management over the network

 

Refer to “Setting Up SNMP Management” on page 49.

 

 

Setting Up

This section describes how you can set up command line interface

Command Line

management using a local console port connection or over the network.

Interface

 

Management

 

CLI Management via

To manage a Switch using the command line interface via the local

the Console Port

console port connection:

1Ensure you have connected your workstation to the console port correctly as described in “Connecting to the Console Port” on page 38.

2Your Switch is now ready to continue being managed and/or configured through the CLI via its console port.

CLI Management over

To manage a Switch using the command line interface over a network

the Network

using Telnet:

1Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 32.

2Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.

3Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:

c:\ ping xxx.xxx.xxx.xxx

(where xxx.xxx.xxx.xxx is the IP address of the Switch)

If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.

Image 47
Contents SuperStack 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Contents Setting UP for Management PIN-OUTS Index Regulatory Notices About this Guide Convention Description ConventionsIcon Description Documentation RelatedProduct Introducing Series About the SwitchFront View Detail Switch 4200 SeriesIntroducing the Superstack 3 Switch 4200 Series Port Status LEDs Gbic ports Fiber GBICs1000BaseT GBICs Color Indicates Port Status LEDs 10BASE-T/100BASE-TX portsAlert LED Power/Self Test LEDColor Indicates Unit LEDsRear View Detail System RPS. See Connecting a Redundant Power System onQuality of Service QoS Feature Switch 4200 Series Automatic IP ConfigurationDuplex Mode Rmon AlarmInstalling the Switch Site Package ContentsChoosing a Suitable Rack-mounting Fitting a bracket for rack-mounting Repeat steps 2 and 3 for the other side of the Switch100 m 328 ft can be used for stacking Stacking UnitsUnit line up with the recesses of the lower unit On the unit above. Cable lengths of between 14 cm 5.5Sequence Power-upPowering-up Switch 4200 SeriesColor State Power/Self Test LED colorsCross-over Cable Straight-through Cable Fiber cablesTransceivers Gbic OperationApproved Gbic The 3Com approved Gbic transceivers are Installing the Switch Gbic Installing the Switch Setting UP for Management Overview Setting UpConfigure IP information manually for your Switch or view Automatically configured IP informationAutomatic IP Configuration Manual IP ConfigurationSetting UP for Management Pre-requisites Manually Configuring IP InformationSetting Up the Switch with IP Information Connecting the Workstation to the SwitchConfiguring the Workstation with IP Information Using Command Line Interface via Telnet Example top-level command line interface menu Connecting a workstation to the Switch via the console port Setting Up the Switch with IP Information Example top-level command line interface menu Automatically Configured IPViewing Viewing Automatically Configured IP Information Viewing IP Information via the Console Port Methods of Managing a Switch Refer to Setting Up Command Line Interface Management on CLI Management via Command LineNetwork Using Telnet Interface ManagementChoosing a Browser Setting Up WebInterface Management workstation Setting Up SnmpManagement Protocol Snmp can manage a Switch if Over the NetworkUser Default Name Password Access Level Default UsersSecurity Device User Modify operation on the web interface Setting UP for Management For Technical Support information, see Appendix D Problem SolvingOn powering-up, the Power/Self Test LED lights yellow Solving ProblemsSolutions below Power LED does not lightIP Addressing ProblemsSolving Communication Problems Solving Hardware Snmp fan fail trap hardware failureHow do you obtain a registered IP Address? Solving StackFormation Solving Software Upgrade Problems Problem Solving Safety Information This must be approved for the country where it is used Important Safety InformationImportant Safety Information ’information de Sécurité Importante ’information de Sécurité Importante Wichtige Sicherheitsinformationen Vorsicht Europe Appendix a Safety Information Pin to 9-pin Null Modem CablePC-AT Serial Cable Pin to RS-232 25-pinRJ-45 Pin ConnectorsPin Number Signal Function Modem CablePin Assignments RJ-45 connectors1000BASE-T RJ-45 Pin assignments Switch 4226T 3C17300 Terminal Emulation Protocols Used for AdministrationStandards Supported Snmp Switch 4250T 3C17302Switch 4228G 3C17304 Online Technical ServicesUsername anonymous From this region, enter the URL Asia, Pacific RimFrom this region, e-mail Europe, Middle East and AfricaEurope, Middle East, and Africa Asia, Pacific RimCountry Telephone Number Asia, Pacific Rim Country Telephone Number Latin America Index Snmp Regulatory Notices
Related manuals
Manual 79 pages 26.18 Kb

C17304, C17302, 3C17300 specifications

The 3Com C17304, 3C17300, and C17302 are notable models in the 3Com networking product line, renowned for their performance and technological advancements. These models cater to various networking environments, providing robust solutions for both small and medium-sized businesses as well as larger enterprises seeking reliable connectivity.

The 3Com C17304 is recognized for its formidable capacity and flexibility. It offers a high port density, which allows for multiple devices to connect without compromising performance. This model features built-in support for Power over Ethernet (PoE), enabling the powering of devices such as IP cameras and phones directly through the network cable. The 3Com C17304 is designed with advanced security features, including integrated VLAN support for traffic segmentation and enhanced security protocols to protect sensitive data.

The 3C17300 is another essential player in this lineup, embodying versatility and ease of use. This model is equipped with a user-friendly interface that simplifies network management, making it accessible for IT professionals at all levels. The 3C17300 includes capabilities for Layer 2 switching, providing efficient data forwarding with minimal latency. Its intelligent features, such as link aggregation and QoS (Quality of Service), ensure optimized bandwidth utilization while prioritizing critical applications.

Meanwhile, the C17302 is specifically engineered for performance-driven environments. It excels in delivering high-speed connectivity with its support for Gigabit Ethernet, significantly enhancing data transfer rates. The C17302 also incorporates advanced routing capabilities, allowing for dynamic network management and improved performance in complex network topologies. Furthermore, this model boasts reliability with redundancy features designed to minimize downtime, ensuring consistent access to network resources.

All three models leverage innovative technologies to deliver superior performance. They support various standards such as IEEE 802.1Q for VLAN tagging and IEEE 802.3ad for link aggregation. User-centric features like SNMP for network monitoring and troubleshooting enhance the overall management experience. These switches are built to provide scalability, enabling businesses to expand their networks seamlessly as demands grow.

In summary, the 3Com C17304, 3C17300, and C17302 showcase advanced features, reliability, and effective performance, making them integral components of modern networking solutions. Ideal for a range of applications, they help businesses optimize their network infrastructure while maintaining robust security and efficient data handling.