RJ-45

Signal

Direction

DB-9

3

TXD

3

 

 

 

 

4

CD

1

 

 

 

 

5

GND

--

5

 

 

 

 

6

RXD

2

 

 

 

 

7

DSR

6

 

 

 

 

8

CTS

8

 

 

 

 

Connection Procedure

When you want to use the terminal to configure the switch, follow these steps to connect a terminal device to the switch using the console cable:

Step1 Plug the DB-9 female connector of the console cable to the serial port of the console terminal or PC.

Step2 Connect the RJ-45 connector of the console cable to the console port of the switch.

Pay attention to the mark on the console port and be sure to plug the connector to the correct port.

z

z

When connecting a PC to a powered-on switch, you are recommended to connect the DB-9 connector of the console cable to the PC before connecting the RJ-45 connector to the switch. When disconnecting a PC from a powered-on switch, you are recommended to disconnect the DB-9 connector of the console cable from the PC after disconnecting the RJ-45 connector from the switch.

Setting Terminal Parameters

When setting up the configuration environment through the console port, the terminal or PC can use the terminal emulation program to communicate with the switch. You can run the HyperTerminal of the Windows operating system to connect to other PCs, network devices, and Telnet sites. For detailed information and the use of the HyperTerminal, refer to the HyperTerminal Help documentation in Help and Support Center on the PC running the Windows operating system.

In the following configuration procedure, Windows XP HyperTerminal is used to communicate with the switch.

1)Start the PC and run the terminal emulation program.

2)Set terminal parameters as follows:

zBits per second: 19,200

4-2

Image 41
Contents 3Com Switch 4510G Family Environmental Statement About This Manual Chapter ContentsOrganization ConventionsObtaining Documentation Related DocumentationCreate Folder Convention DescriptionTable of Contents Page Overview Switch 4510G 24-Port Switch 4510G 48-PortSwitch 4510G 24-Port Introduction to Switch 4510GSwitch 4510G 48-Port Ports SpecificationConsole Port 10/100/1000Base-T Ethernet PortModel SFP port 10/100/1000Base-T Ethernet port SFP PortCombo Port System Status LED LEDsRPS Status LED LEDsSeven-Segment LED Port Mode LEDMark Status Description System status Seven-segment LED DescriptionStatus System status Seven-segment LED Description Status Description Port mode Ethernet port status10/100/1000Base-T Auto-Sensing Ethernet Port Status LED Interface Module Status LED Optional Interface ModulesSFP Port Status LED Short-haul Dual-Port 10 GE CX4 Interface Module CX4 Cable Connector type LengthDistance Central Max Transceiver Connector Fiber TransmissionDual-Port 10 GE XFP Interface Module Dual-Port 10 GE SFP+ Interface Module One-port 10 GE XFP Interface ModuleTransceiver Central Max Connector Fiber Transmission Cable type DistanceDescription of LEDs of Interface Modules Installation Site Safety PrecautionsCleanness Temperature/HumidityElectromagnetic Susceptibility Gas Maximum concentration mg/mLaser Safety Installation ToolsInstallation Flow of the Switch Installing the SwitchIntroduction to Mounting Bracket Use Front Mounting Brackets to Install a SwitchUse Front Mounting Brackets and a Tray to Install a Switch When a Grounding Strip is Available Mounting the Switch on a WorkbenchConnecting the Grounding Cable Page Other Installation Sites Where a Grounding Conductor Can be BuriedSwitch module Power supply mode Connection method Connecting the Power CordsConnecting the AC Power Cord 9Connect an AC power cord to a horizontal AC power socket Connecting the RPS Power Cord Installing an Interface ModuleRemoving an Interface Module Installing an Interface CardRemoving Dedicated CX4/SFP+ Cable Installing Dedicated CX4/SFP+ CableTask Remarks Installing Switches for an IRFInstallation Flow for an IRF For details, see Installing an Interface Module Drawing a Plan for an IRF with SwitchesSelect the proper interface modules and cables Page 22Cable connections for an IRF with 1-port interface modules Verifying the InstallationConnecting the Console Cable Setting up the Configuration EnvironmentRJ-45 Signal Direction DB-9 Console CableConnection Procedure Setting Terminal Parameters4Set the serial port used by the HyperTerminal connection 6HyperTerminal window Powering on the Switch Booting the SwitchChecking before Powering on the Switch Describes the fields above 2Description on the fields Changing the Startup Mode Enter Y. The system displays the following information BUS Clock Speed 33MHz Memory Size 128MB Mac Address Page Introduction to Loading Modes Loading Software Through the Boot ROM MenuBoot Menu Press Ctrl + B. The system displays Introduction to Xmodem Loading Software Using Xmodem Through Console PortROM file effective Required2Properties dialog box Cccccccccccccccccc CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCdone Loading host software Loading Software Using Tftp through Ethernet PortLoad File name Introduction to FTP Loading Software Using FTP Through Ethernet PortDescription Loading Software Through CLI Loading Software Using FTPUpdate the Boot ROM program on the switch Loading Software Using TftpMissing User Password Password Missing FailureMissing Boot ROM Password Software Loading FailureAC input Power Supply FailureRPS input RPS&AC inputSteady red Fan FailureMark State System status LED Troubleshooting when the terminal display is illegible Configuration System FailureTroubleshooting when there is no terminal display

4510G specifications

The 3Com 4510G is a high-performance, stackable switch designed to meet the demands of modern enterprise networks. This switch is part of the 3Com switch family, known for its reliability, ease of use, and advanced features tailored for both small and medium-sized businesses, as well as larger enterprises.

One of the standout features of the 3Com 4510G is its high-density 10/100/1000 Mbps Gigabit Ethernet ports. With a configuration of up to 48 ports, this switch allows for efficient data transfer and connectivity among devices in the network. The switch also supports Power over Ethernet (PoE), enabling it to deliver power to PoE-enabled devices like IP phones, wireless access points, and security cameras, simplifying deployment and reducing cable clutter.

In terms of performance, the 3Com 4510G offers non-blocking architecture, which ensures that any port can handle its maximum throughput without causing bottlenecks. This switch is equipped with a high-performance switching capacity, allowing for seamless data flow and minimizing latency, which is critical for applications such as voice over IP (VoIP) and video conferencing.

The 3Com 4510G also provides advanced Layer 2 and Layer 3 routing capabilities. It supports features like VLANs, link aggregation, and multicast routing, which enhance network segmentation and optimize traffic management. The switch supports a comprehensive set of security features, including Access Control Lists (ACLs) and port security, to safeguard the network against unauthorized access.

Management is another strong suite of the 3Com 4510G. It supports Simple Network Management Protocol (SNMP) for effective network monitoring and management, as well as a user-friendly web interface and command-line interface (CLI) for easy configuration. Network administrators can easily troubleshoot and maintain the switch through these interfaces, ensuring optimal performance.

Additionally, the 3Com 4510G is designed with energy efficiency in mind, adhering to environmental standards, and thereby reducing operational costs over time.

With its robust feature set, advanced technologies, and high reliability, the 3Com 4510G switch stands out as an excellent choice for organizations looking to build a scalable and efficient network infrastructure. Its combination of performance, ease of management, and security makes it a valuable asset for meeting current and future networking needs.