Roland DIF-AT24 owner manual BRC settings, Set the VS-2400CDs parameters as follows

Page 14

Connections and settings

Settings

Sampling Frequency settings

Set the sampling frequency of the VS-2400CD and ADAT device to the same setting (48 kHz).

Master Clock settings

Master clock device

VS-2400CD setting

 

DIF-AT24

 

MASTER CLK switch

 

 

 

 

 

 

VS-2400CD

PROJECT PARAMETER screen

R-BUS

MASTER CLOCL

INT

 

 

 

 

 

ADAT device

PROJECT PARAMETER screen

ADAT

MASTER CLOCL

R-BUS

 

 

 

 

 

 

You'll also need to set the Master Clock for the ADAT device. For details on this setting, refer to the owner's manual for the ADAT device.

Synchronization settings

Set the VS-2400CD's parameters as follows.

MIDI PARAMETER screen

SysEx. Rx. Sw. On

MMC MODE.. SLAVE

MMC SOURCER-BUS

SYNC PARAMETER screen

SYNC MODE . EXT

EXT SYNC SOURCER-BUS

FRAME RATE..................... Same setting as the software.*

BRC settings

1

2

3

Press [EDIT] [GEN SYNC] [GEN SYNC].

The screen will indicate “Generate Sync.”

Use [][] to select “MIDI: MTC,” and press [EDIT].

[EDIT] will go dark.

Press [GEN SYNC].

[GEN SYNC] will light, and the BRC will output MTC.

14

Image 14
Contents Copyright 2003 Roland Corporation Main FeaturesCongratulations on your purchase of the Roland DIF-AT24 Page Avis Maintenance Power SupplyPlacement Additional PrecautionsContents Rear Panel Panel descriptionsFront Panel These are used mainly for MTC synchronizationTurning the power off Turning the power on/offTurning the power on Connections and settings Connecting the VS-2400CD and a computerSynchronization settings Sampling Frequency settingsMaster Clock settings Set the VS-2400CDs parameters as follows MMC settingsAdat Optical Adat Optical OUT Sync Parameter screen YNC Parameter screen Connecting the VS-2400CD and an Adat device Connecting the VS-2400CD with an Adat device and BRC BRC settings Set the VS-2400CDs parameters as followsMV-8000 settings Make connections as shown in the diagramInformation VM-7100/7200 と接続する場合