The troubleshooting section is used as a guide to understanding the capabilities of the CrystalView DVI Fiber and for general troubleshooting. If you have any problems or questions concerning the installation, operation or usage of the CrystalView DVI Fiber that is not covered in this manual, please contact Rose Electronics for technical support.

There isn’t a picture.

Check the power supply connection at the Local unit. Is the Power (Red LED) at the Local unit illuminated? If not, the internal power-supply may be damaged or there may be an internal error.

Check the power supply connection at the remote unit. Is the Power (Red LED) at the Remote unit illuminated? If not, the internal power- supply may be damaged or there may be an internal error.

Check that the Interconnection cable is connected at the Local Unit and the Remote Unit. Is the Link Status LED illuminated? If not, there may be a problem with the Interconnection cable:

Are there Errors through data transmission over fiber Cable? Is the Data Error LED illuminated or blinking? If yes, check cable length and environment.

Video Okay LED is dark: CPU does not provide a video signal – Check settings of the graphic card. Try connecting a monitor to the local output,

to see, whether there is a signal or not. Keyboard

The PC boots fine with no error messages but the keyboard does not work

Wrong cable plugged in, keyboard and mouse cables reversed.

Try a different model of keyboard. If the new keyboard works then original one may be incompatible

Check that the Interconnection cable is connected at the Local Unit and the Remote Unit. Is the Link Status LED illuminated (see page 23)?

PS2-Mouse

A mouse cursor appears on the screen, but the mouse does not work

Wrong cable plugged in, keyboard and mouse cables reversed.

Try a different model of mouse

The system does not detect a PS/2 mouse, or the application cannot find the mouse.

Ensure that the Local Unit is connected to the PC keyboard port to provide power

10CRYSTALVIEW DVI FIBER INSTALLATION AND OPERATIONS MANUAL

Image 14
Contents CrystalView DVI Fiber Limited Warranty FCC/IC STATEMENTS, EU Declaration of Conformity ModelsTable of Contents System introduction IntroductionDisclaimer Compatibility FeaturesPackage contents Models / Connectors Single Video ModelsModels Dual Video RearCables CrystalView DVI Fiber to Rose switch cableCables Receiver to KVM station cableInstallation InstallationCable type Maximum distance Applying powerTransmitter to Receiver cabling Diagnostic LED Indicators Power Data Error Status Video OKOperation Instructions Operating instructionsTroubleshooting TroubleshootingMaintenance and Repair Service and SupportService Information Technical SupportSafety SafetyServicing Safety and EMC Regulatory Statements Safety informationGrounding Appendix A. General specifications AppendicesPart Number Singlemode Description Appendix B. Parts and cablesPart Number Multimode Description Stancliff Road Phone 281 Houston, Texas