User selectable settings
(PC and SUN models)
Dipswitch SW1 on the Remote Units PCB has four switches that allow you to change settings from their factory set values. SW1 settings only apply to the CrystalView Dual model. If your model is a Single version, switches
(Factory settings are in BOLD.)
Switch | Function | Left (OFF) | Right (ON) |
1 | Privacy mode | Enabled | Disables |
|
|
|
|
2 | Lockout time | 15 sec. | 2 sec. |
|
|
|
|
3 | Activation method | Kbd. or mouse | Keyboard |
|
|
|
|
4 | Scroll lock key | Normal keyboard | Commands to |
|
| function | CrystalView |
|
|
|
|
Table 1. User settings (PC/SUN models)
(PC-Serial/Audio model)
The CrystalView models with the Serial/Audio option have Dipswitch SW1 switches 1, 3, and 4 inoperable. Dipswitch 2 sets either the right or left control key to be the key to initiate commands to the CrystalView. (Press and release the control key, then enter the command to send to the CrystalView.) See Figure 5 for SW1 setting and location.
Factory settings are in BOLD
Switch | Function | Left (OFF) | Right (ON) |
1 | N/A | N/A | N/A |
|
|
|
|
2 | Command key | Right control key | Left control key |
|
|
|
|
3 | N/A | N/A | N/A |
|
|
|
|
4 | N/A | N/A | N/A |
|
|
|
|
Table 2. User settings
(MINI model)
For normal scroll lock key operation set Dipswitch #2 on the bottom of the Remote Unit to “ON” (default = “Off”).
CRYSTALVIEW INSTALLATION AND OPERATIONS MANUAL
17