TROUBLESHOOTING

Troubleshooting

The troubleshooting section is used as a guide to understanding the capabilities of the CrystalView and for general troubleshooting. If you have any problems or questions concerning the installation, operation or usage of the CrystalView that is not covered in this manual, please contact Rose Electronics for technical support.

PC boots with no error messages but keyboard does not work.

nCable is loose; re-seat keyboard cable at the CPU and the Local CrystalView Unit reset the keyboard and mouse.

nKeyboard and mouse cables reversed.

nTry a different model of keyboard. If the new keyboard works, the original one may not be compatible. Some older auto- sensing keyboards may not work with this product.

Wrong or missing characters from those typed.

nThe keyboard may be in the wrong mode. Reset the keyboard.

nPower down and reboot the system.

PC always comes up with a keyboard error message at boot.

nIf the system appears to work fine after pressing F1 or ESC, adjust your BIOS setup so that the PC does not test the keyboard.

Connecting a keyboard to the Unit affects video.

nChange to a newer keyboard. Some older model keyboards require a current higher than that supplied by the CrystalView.

nInstall a supplemental power supply to the keyboard connector on the Local Unit. See Appendix C for part number.

PS/2 cursor appears on the screen, but mouse doesn’t work.

nReset the mouse. (See Table 4)

nCable is loose, re-seat the mouse cable and reset the mouse. Keyboard and mouse cables reversed.

nTry a different model of mouse.

nPower off and on the Remote Unit

Mouse movement is erratic.

nReset the keyboard and mouse. (See Table 4)

nIssue a Null Mouse Command (up to 3 times), (See Table 5)

nReload the application and/or reboot the PC. If this problem persists call Rose Electronics technical support.

CRYSTALVIEW INSTALLATION AND OPERATIONS MANUAL

21

Image 27
Contents Installation and Operations Manual Table of Contents Limited Warranty FCC/IC STATEMENTS, EU Declaration of Conformity Stancliff Road Appendices TablesIntroduction DisclaimerSystem introduction Features Package contents CompatibilityRose Electronics web site About this manual Remote Unit Local Single Unit Local Dual Unit ConnectorsModels CrystalView PC-modelSun model CrystalView SUN modelCrystalView PC-Serial/Audio model Mini model CrystalView Mini modelCrystalView cables CablesPower adapter Serial cableAudio cable Installation InstallationMini model See Figure PC-Serial/Audio model only. See FigureConnecting cables PC / SUN / Serial/AudioLocal / Remote unit cabling Sun cabling Mini cabling Connecting to a Rose switch Applying power All modelsMini Model No video compensation is required for the Mini model Right control key User selectable settings PC and SUN modelsSwitch Function Left OFF Right on PC-Serial/Audio modelDual, PC Serial/Audio model specific notes Operating Instructions Operating instructions- All unitsOperating instructions Dual unit Null mouse command ResetTroubleshooting TroubleshootingKeyboard and Mouse have locked up Video picture is not sharp or is smearedOnly video is required, but no picture appears No sound at the Remote Units speakers or headphones Picture on monitor is black and white, not colorConstant vertical wobble appears down the screen Technical Support ServiceService Information Maintenance and RepairSafety SafetySafety and EMC Regulatory Statements GroundingServicing Appendices Appendix A. General specificationsAppendix B. UTP/STP connection Appendix A1. Serial option specificationsAppendix A2. Audio option specifications Wire ColorAppendix C. Parts and cables Part Number Description Appendix D. Firmware updatesAppendix F. Rack mount illustration Appendix E. Rack mount instructions