TDK iHA48040A033V* specifications Thermal Performance, 105 115

Page 10

Data Sheet: Veta® iHA48040A033V*, 3.3V/40A Output Half Brick Series

Thermal Performance:

 

40

 

 

 

 

 

 

 

 

 

( A )

30

 

 

 

 

 

 

 

 

 

u t p u t C u r r e n t

20

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

25

35

45

55

65

75

85

95

105

115

 

 

 

 

 

Ambient Temperature (oC)

 

 

 

 

 

 

 

NC 0.3 m/s (60 LFM)

0.5 m/s (100 LFM)

 

1.0 m/s (200 LFM)

 

 

 

 

 

1.5 m/s (300 LFM)

 

IMS LIMIT

 

 

 

 

 

iHA48040A033V-001 maximum output current vs. ambient temperature at nominal input voltage for airflow rates natural convection 0.3 m/s (60lfm) to 3.0m/s (600lfm) with airflow from output to input.

 

40

 

 

 

 

 

 

 

 

 

(A)

30

 

 

 

 

 

 

 

 

 

Current

 

 

 

 

 

 

 

 

 

 

Output

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

25

35

45

55

65

75

85

95

105

115

 

 

 

 

 

Ambient Temperature (oC)

 

 

 

 

 

 

NC 0.3 m/s (60 LFM)

 

0.5 m/s (100 LFM)

 

1.0 m/s (200 LFM)

 

 

 

1.5 m/s (300 LFM)

 

2.0 m/s (400 LFM)

 

IMS LIMIT

 

 

iHA48040A033V-001 maximum output current vs. ambient temperature at nominal input voltage for airflow rates natural convection 0.3 m/s (60lfm) to 3.0m/s (600lfm with airflow from input to output.

 

 

5.0

 

 

 

 

 

 

Resistance,

 

4.5

 

 

 

 

 

 

 

4.0

 

 

 

 

 

 

 

3.5

 

 

 

 

 

 

Thermal

C/W

3.0

 

 

 

 

 

 

o

 

 

 

 

 

 

 

A ,

 

 

 

 

 

 

 

Ambient

Θ C

2.5

 

 

 

 

 

 

2.0

 

 

 

 

 

 

to

 

 

 

 

 

 

 

 

Case

 

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

 

0.5

 

 

 

 

 

 

 

 

0

0.5

1

1.5

2

2.5

3

 

 

 

 

 

Airflow, m/s

 

 

 

 

 

 

 

NO HS

1/4" HS

1/2" HS

1" HS

 

iHA48040A033V-001 Case to Ambient Thermal Resistance vs. Airflow rate

©2007 TDK Innoveta Inc.

' (877) 498-0099

iHA Datasheet 040207

10/17

 

 

 

Image 10
Contents TDK Innoveta Inc Standard Features Optional FeaturesOrdering information Product OfferingMechanical Specification Recommended Hole Pattern top view Pin AssignmentAbsolute Maximum Ratings Common Input CharacteristicsElectrical Data Output Characteristic Min Typ Max Unit Electrical Characteristics IHA48040A033V-001 Load Regulation+ 5% + Increase in Output Voltage, Δ % Thermal Performance 105 11511/17 Wind Tunnel Test Setup Figure Thermal Management13/17 Operating Information An On/Off Control CircuitRdown = 100% − 2 kΩ Input/Output Ripple and Noise Measurements Safety ConsiderationsReliability Warranty Quality