TDK iHA48040A033V* specifications Electrical Characteristics, IHA48040A033V-001 Load Regulation

Page 7

Data Sheet: Veta® iHA48040A033V*, 3.3V/40A Output Half Brick Series

Electrical Characteristics:

iHA48040A033V-001 Efficiency

iHA48040A033V-001 Power Dissipation

Ta = 25 Deg C.

 

95

 

 

 

 

 

 

 

 

 

 

η(%)

90

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

 

Efficiency,

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

0

4

8

12

16

20

24

28

32

36

40

Output Current (A)

Vin = 36V Vin = 48V Vin = 75V

Ta = 25 Deg C.

 

14

 

 

 

 

 

 

 

 

 

 

(W)

12

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

Dissipation

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

4

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0

4

8

12

16

20

24

28

32

36

40

Output Current (A)

Vin = 36V Vin = 48V Vin = 75V

iHA48040A033V-001 Typical Efficiency vs. Output Current at Ta=25 degrees.

iHA48040A033V-001 Typical Power Dissipation vs. Output current at Ta=25 degrees

iHA48040A033V-001 Load Regulation

Ta = 25 Deg C.

 

3.302

 

 

 

 

 

 

 

 

 

(V)

3.3018

 

 

 

 

 

 

 

 

 

Voltage

3.3016

 

 

 

 

 

 

 

 

 

3.3014

 

 

 

 

 

 

 

 

 

3.3012

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

3.301

 

 

 

 

 

 

 

 

 

3.3008

 

 

 

 

 

 

 

 

 

3.3006

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

8

12

16

20

24

28

32

36

40

Output Current (A)

Vin = 36V Vin = 48V Vin = 75V

iHA48040A033V-001 Typical Output Voltage vs. Load Current at Ta = 25 degrees

iHA48040A033V-001 Typical startup characteristic from on/off at full load. Upper trace - on/off signal, lower trace – output voltage

iHA48040A033V-001 Typical startup characteristic from input voltage application at full load. Upper trace - input voltage, lower trace – output voltage

iHA48040A033V-001 Typical transient response. Load step from 50% to 75% of full load with 0.1A/uS. Lower trace – output current , upper trace – output voltage

©2007 TDK Innoveta Inc.

' (877) 498-0099

iHA Datasheet 040207

7/17

 

 

 

Image 7
Contents TDK Innoveta Inc Optional Features Standard FeaturesProduct Offering Ordering informationRecommended Hole Pattern top view Pin Assignment Mechanical SpecificationAbsolute Maximum Ratings Common Input CharacteristicsElectrical Data Output Characteristic Min Typ Max Unit IHA48040A033V-001 Load Regulation Electrical Characteristics+ 5% + Increase in Output Voltage, Δ % 105 115 Thermal Performance11/17 Thermal Management Wind Tunnel Test Setup Figure13/17 An On/Off Control Circuit Operating InformationRdown = 100% − 2 kΩ Input/Output Ripple and Noise Measurements Safety ConsiderationsReliability Quality Warranty