Choosing a Setup Location

Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches).

Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing.

This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets, etc.).

This product is not suitable for use with visual display work place devices accord- ing to §2 of the the German Ordinance for Work with Visual Display Units.

!

Warnings and Precautions!

Rack Precautions

!

Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.

In a single rack installation, stabilizers should be attached to the rack.

In multiple rack installations, the racks should be coupled together.

Always make sure the rack is stable before extending a component from the rack.

You should extend only one component at a time - extending two or more si- multaneously may cause the rack to become unstable.

Server Precautions

Review the electrical and general safety precautions in Chapter 4.

Determine the placement of each component in the rack before you install the rails.

Install the heaviest server components on the bottom of the rack first, and then work up.

2-2

Image 18
Contents Super Manual Revision 1.0a Release Date December 29 Preface About This ManualManual Organization Advanced Motherboard Setup Advanced Chassis SetupBios Preface Table of Contents System Safety Viii Advanced Chassis Setup Page Chapter Introduction OverviewMotherboard Features Intel X58/ICH10R Chipset System Block Diagram Server Chassis Features Europe Contacting SupermicroHeadquarters Asia-PacificPage Chapter Server Installation Preparing for SetupUnpacking the System Choosing a Setup Location Rack PrecautionsAmbient Operating Temperature Rack Mounting ConsiderationsInstalling the System into a Rack Identifying the Sections of the Rack RailsInstalling the Chassis Rails Installing the Rack RailsInstalling the Server into the Rack Installing the Server into a RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Accessing the Inside of the System FigureAccessing the Inside of the System Checking the Drive Bay Setup Checking the DrivesChapter System Interface Reset ButtonPower Control Panel ButtonsOverheat/Fan Fail HDDSerial ATA Drive Carrier LEDs Page Chapter System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Installing the Onboard BatteryChapter Advanced Serverboard Setup Handling the ServerboardServerboard Installation UnpackingConnecting Power Cables Connecting CablesConnecting Data Cables Connecting the Control PanelControl Panel Header Pins I/O PortsInstalling the Processor and Heatsink Installing an LGA1366 ProcessorCPU Installing a Passive CPU Heatsink Removing the Heatsink Installing Memory Modules Installing & Removing DIMMsMemory Support Maximum Memory PossibleAdding PCI Expansion Cards Possible System Memory Allocation & AvailabilityServerboard Details X8STi Layout Not drawn to scaleJumper Description Default Setting X8STi Quick ReferenceConnector Definitions HDD LED/UID Switch Power On LEDOverheat/Fan Fail/UID LED ATX PS/2 Keyboard and PS/2 Mouse Ports NMI ButtonFan Headers Serial PortsExternal Speaker/Internal Buzzer Chassis IntrusionWake-On-LAN Overheat/Fan Fail LEDUniversal Serial Bus USB Power Supply SMBus HeaderOnboard Power LED Sgpio HeadersButton Power Supply Fail LED HeaderAlarm Reset Unit Identifier ButtonExplanation of Jumpers Jumper SettingsVGA Enable/Disable Cmos ClearLAN1/2 Enable/Disable Watch Dog Enable/DisableUSB Wake-Up SMBus to PCI Slots Onboard IndicatorsBMC Enable/Disable LAN1/2 LEDsOnboard Power LED LE1 BMC Heartbeat LEDFloppy Drive Connector Floppy and Sata PortsSata Ports Installing Software Supero Doctor Supero Doctor III Interface Display Screen Remote Control Page Chapter Advanced Chassis Setup Static-Sensitive DevicesControl Panel Chassis Front ViewSystem Fans System Fan FailureDrive Bay Installation/Removal Accessing the Drive BaysSerial ATA Drive Installation Mounting a Sata Drive in a Drive Carrier DVD-ROM Drive Installation Sata Power CablesPower Supply Power Supply FailurePage Chapter Starting Bios Setup UtilityHow To Change the Configuration Data IntroductionMain Setup Starting the Setup UtilitySystem Time/System Date Processor System MemoryAdvanced Setup Configurations Xboot FeatureXProcessor & Clock Options Active Processor Cores Hardware Prefetcher Available when supported by the CPUClock Spread Spectrum Intel Eist Technology~ 3 Core Ratio Limit Intel Turbo Boost Configuration Turbo Ratio Limit ProgramCore Ratio Limit TDC Limit OverrideXAdvanced Chipset Control Memory Frequency Memory ModeQPI L0s and L1 Demand ScrubbingHigh Performance Event Timer Inlet TemperatureTemperature Rise Air FlowIntel I/OAT Active State Power ManagementIntel VT-d USB FunctionsFloppy a IDE Detect Timeout secXide / Floppy Configuration SATA#1 ConfigurationType LBA/Large ModePIO Mode Block Multi-Sector TransferDMA Mode A.R.T. For Hard disk drives32Bit Data Transfer XPCI/PnP Configuration XRemote Access Configuration XSuper IO Device ConfigurationXHardware Health Configuration CPU Temperature/System Temperature System TemperatureCPU Temperature Xacpi Configuration XTrusted Computing Xipmi Configuration X8STi-F/X8STi-3F OnlySet PEF Configuration Clear BMC System Event LogSet LAN Configuration AbledXEvent Log Configuration User Password Security SettingsSupervisor Password Change Supervisor PasswordBoot Configuration XBoot Device PriorityBoot Sector Virus Protection XRemovable Drives Exit OptionsXHard Disk Drives XCD/DVD DrivesDiscard Changes and Exit Load Optimal DefaultsLoad Fail-Safe Defaults Discard ChangesAppendix a Post Error Beep Codes Recoverable Post Error Beep CodesPage Appendix B Installing the Windows OS Installing Windows on RAID SystemsInstalling Windows on Non-RAID Systems Appendix C System Specifications ProcessorsChassis Appendix C System Specifications

5016T-TB specifications

The Super Micro Computer 5016T-TB is a powerful and versatile server chassis designed to meet the increasing demands of data centers and enterprise environments. Tailored for high-performance computing, it combines a robust architecture with advanced technologies, making it an ideal choice for various applications, including cloud computing, virtualization, and mission-critical workloads.

One of the standout features of the 5016T-TB is its compact form factor, which optimizes space in server racks while providing exceptional performance. The chassis supports dual Intel Xeon processors, allowing users to harness substantial computing power for processing complex tasks. Additionally, it accommodates up to 512GB of DDR3 ECC memory, ensuring data integrity and stability, crucial for applications in need of reliability.

The server is equipped with six hot-swap drive bays, supporting both SAS and SATA drives, which allows for rapid data access and redundancy. This design contributes to enhanced data security and availability, as swapping out drives can be done without interrupting operations. The 5016T-TB supports multiple RAID configurations, providing users with flexible options for storage management and fault tolerance.

With a focus on connectivity, the Super Micro 5016T-TB features several PCI Express slots, enabling users to expand functionality with additional networking or storage cards. It comes with onboard Intel Gigabit Ethernet ports, ensuring high-speed network connections essential for data-intensive applications. The server chassis is also designed for efficient cooling, incorporating optimized airflow patterns to maintain optimal operating temperatures, which prolongs the lifespan of components and enhances overall performance.

In terms of energy efficiency, the 5016T-TB is compliant with various environmental standards and features advanced power management technologies. This not only reduces operational costs but also decreases the carbon footprint of the data center.

Another significant characteristic of this server is its management capabilities. Supermicro provides dedicated management tools for monitoring system health, temperature, and power consumption, which are essential for proactive infrastructure management.

With its robust build, substantial scalability, and advanced features, the Super Micro Computer 5016T-TB stands out as a reliable option for businesses looking to enhance their computing infrastructure. Whether for virtualized environments or resource-intensive applications, it represents a commitment to delivering high performance and flexibility for diverse IT needs.