SC512 Chassis Manual
4-2 Control Panel Buttons
There are two
Reset: The reset button is used to reboot the system.
Power: The main power switch is used to apply or remove power from the power supply to the server system. Turning off system power with this button re- moves the main power but keeps standby power supplied to the system. Therefore, you must unplug system before servicing.
4-3 Control Panel LEDs
The control panel located on the front of the SC512 chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Overheat/Fan Fail: When this LED flashes it indicates a fan failure. When continuously on (not flashing) it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room tem- perature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly.
This LED will remain flashing or on as long as the overheat condition exists.