Power should always be disconnected from the system when removing or in- stalling main system components, such as the serverboard, memory modules and the DVD-ROM and floppy drives (not necessary for hot-swappable drives). When disconnecting power, you should first power down the system with the operating system and then unplug the power cords from all the power supply modules in the system.

When working around exposed electrical circuits, another person who is fa- miliar with the power-off controls should be nearby to switch off the power, if necessary.

Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.

Do not use mats designed to decrease electrostatic discharge as protection from electrical shock. Instead, use rubber mats that have been specifically designed as electrical insulators.

The power cord must include a grounding plug and must be plugged into a grounded electrical outlet.

Serverboard battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarities This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

DVD-ROM laser: CAUTION - This server may have come equipped with a DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any uncon- ventional way.

2-2

Image 14
Contents Super SC512 Chassis Manual Preface About This ManualManual Organization IntroductionTable of Contents System Interface Vii Viii Chapter Introduction OverviewPeripheral Drives Chassis FeaturesExpansion slots Dual Hard DrivesEurope Contacting SupermicroHeadquarters Asia-PacificReturning Merchandise for Service Electrical Safety Precautions Chapter System SafetyPreparing for Setup Page System Safety Page Chassis Fans Chapter Chassis ComponentsComponents BlowerAir Shroud Where to get Replacement Components Chassis Model OptionsPower Supply Identifying Fan and Blower-Cooled Chassis ModelsBlower-Cooled Chassis Model Model SC512 Chassis Model SC512-200, SC512-260 BlowerModel SC512C Chassis Model SC512C SC512C-200 BlowerModel SC512F Chassis Model SC512F-260 BlowerChassis Models SC512F-410 and SC512F-520 10 Chassis Model SC512F-520L and SC512F-600L Model SC512L 11 Chassis Models SC512L-200 and SC512L-260 BlowerSC512 Chassis Manual Chapter System Interface Chassis LED and ButtonsControl Panel Buttons Control Panel LEDsPage SC512 Chassis Manual General Maintenance Chapter Chassis Setup and MaintenanceInstallation Procedures Removing the Chassis Cover Removing the Chassis CoverInstalling Hard Drives Installing a Hard DriveFlat head Installing the Motherboard Important Motherboard Installation InformationInstalling the Motherboard StandoffsInstalling the DVD or CD-ROM Drive Replacing the DVD or CD-ROMExpansion Slot Setup Installing Expansion CardsInstalling the Air Shroud Air Shroud PlacementInstallation Complete Checking the Airflow in the ChassisSystem Fans System Fan TrayReplacing System Fans System Fan Tray ReplacementInstalling the System Fan Tray Power Supply Power Supply Failure12 Removing the Power Supply Replacing the Power SupplyReplacing the Chassis LED Panel Replacing the Chassis LED PanelSC512 Chassis Manual Unpacking the System Chapter Rack InstallationChoosing a Setup Location Rack Precautions General Server PrecautionsAmbient Operating Temperature Rack Mounting ConsiderationsRack Mounting Instructions Identifying the Sections of the Rack Rails Optional ItemRemoving the Chassis Ears Installing the Inner Rail ExtensionInstalling the Inner Rails Installing the Outer Rails to the Rack Installing the Outer RailsInstalling the Outer Rails to the Server Rack Installing the Chassis into a Rack Installing the ChassisInstaling into a Mid-Mount Position Rack Installing the Chassis into a Rack in Mid-Mount PositionMid-Mount Telco Rack Installing the Server into a Telco Rack Appendix a Cables, Screws Other Accessories Overview Cables Included with SC512 ChassisSC512F-280 Type Length Description SC512F-520L and SC512F-600L Extending Power Cables Front Panel to the MotherboardRouting the Chassis Cables Preparing the Chassis for Cable RoutingRouting Cable 1A from Hard Drive 1B Routing Cable 2A from Hard Drive 2BChecking the Cable Routing Figure A-2 Chassis Cable RoutingChassis Screws StandoffAppendix B Power Supply Specifications MFR Appendix B SC512F Power Supply Specifications