3. Implementation of the communication option cards

3. 10. 7. Programming the Altivar 38 Ethernet parameters

Apart from the drive DHCP name ("DeviceName" parameter), all the parameters that can be accessed using the Altivar 38’s programming terminal are present on an Altivar 61 equipped with a VW3 A3 310 Ethernet card.

They can be accessed from the [ETHERNET] (EtH-)submenu in the [1.9 - COMMUNICATION] (COM-)menu. The correspondence of these parameters between the two types of drive is described in the following table:

Command

Description

Altivar 38

Altivar 61

Value in …

Short

Graphic display terminal or integrated display

 

 

parameter name

terminal

P05/O05

 

 

 

 

 

 

 

 

 

1

IP address

P01/O01 to P04/

AdrIP[1] to AdrIP[4]

[IP card] (IPC-)+ (IPC1) to (IPC4)

 

 

O04

 

 

2

Subnet mask

P01/O01 to P04/

Mask[1] to Mask[4]

[IP Mask] (IPM-)+ (IPM1) to (IPM4)

 

 

O04

 

 

3

Gateway address

P01/O01 to P04/

Gtw[1] to Gtw[4]

[IP Gate] (IPG-)+ (IPG1) to (IPG4)

 

 

O04

 

 

4

DeviceName

P01/O01

DeviceName

XXXX

 

 

 

 

 

5

FDR configuration

P01/O01

Validation

[FDR validation] (FdrU) + (NO/YES)

 

 

 

 

 

 

 

P02/O02

Local Config

[Ethernet local conf] (LCFG) +(OFF/ON)

 

 

 

 

 

 

 

P03/O03

FileDef

[FDR file error] (FdrF) + (OFF/ON)

 

 

 

 

 

6

FDR-Autosave

P01/O01

AutoSave

[FDR autosave] (FdrS) + (NO/YES)

 

configuration

 

 

 

 

 

P02/O02

Timer

[FDR t. autosave] (Fdrt) + 2 to 255

 

 

 

 

 

7

FDR status

P01/O01

Action

[FDR Action] (FdrA) + (IDLE, SAVE, REST, DEL)

 

 

 

 

 

 

 

P02/O02

Status

[FDR state] (FdrE)

 

 

 

 

 

 

 

P03/O03

ErrCode

[FDR Fault] (FdrD) + 0 to 65535

 

 

 

 

 

8

DHCP-FDR server

P01/O01 to P04/

Ip[1] to Ip[4]

[IP FDR] (IPF-) + (IPF1) to (IPF4)

 

IP address

O04

(DHCP-FDR)

 

9

IP Master address

P01/O01 to P04/

Ip[1] to Ip[4]

[IP Process] (IPP-) + (IPP1) to (IPP4)

 

 

O04

(Master)

 

10

IO Scanner

P01/O01

Activation

[Eth IO Scan act] (IOSA) + (OFF/ON)

 

configuration

 

 

 

 

 

P02/O02

Time out

[Ethernet Timeout] (tOUt) + 0 to 60.0

 

 

 

 

 

3.10. 8. Modbus service

Available address fields

In "ATV38 Interchangeability" mode (SE8 mode), addresses W1 to W615, described in the Altivar 38 "Internal communication variables" User’s Manual, can now be accessed in order to insure that an Altivar 38 can be replaced by an Altivar 61.

In order to access these variables by means of TCP/Modbus messaging, a UNIT_ID of 0 must be used, in the same way as before on the Altivar 38.