![](/images/new-backgrounds/1118711/11871185x1.webp)
5.Press <Enter>.
Converting Physical Disk To Non-RAID For PERC H310
Conversion of a Physical Disk to
1.Press <Ctrl> <N> to access the PD Mgmt screen.
A list of physical disks is displayed. The status of the each disk is displayed under State.
2.Press the
3.Press <F2> to display the menu of available actions.
4.Press the
5.Press <Enter>.
Initializing Virtual Disks
CAUTION: A full initialization permanently destroys any existing data on that virtual disk.
Perform the following steps to initialize virtual disks:
1.On the VD Mgmt screen, select Virtual Disk # and press <F2> to display the menu of available actions.
2.Select Initialization and press the
3.Select Start Init. to begin a regular initialization or select Fast Init. to begin a fast initialization. A
4.Repeat the procedures from step 1 to step 3 to configure another virtual disk.
NOTE: The PERC H310 card supports up to 16 virtual disks per controller, and the PERC H710, H710P, and H810 cards support up to 64 virtual disks per controller. The currently configured virtual disks display on the screen.
Checking Data Consistency
Select the Consistency Check (CC) option in the configuration utility to verify the redundancy data in virtual disks that use RAID levels 1, 5, 6, 10, 50, and 60. (RAID 0 does not provide data redundancy.)
If you attempt to run a Consistency Check on a virtual disk that has not been initialized, the following error message is displayed:
The virtual disk has not been initialized. Running a consistency check may result in inconsistent message in the log. Are you sure you want to continue?
You can select Yes or No. If you select Yes, the CC operation continues. If you select No, the operation ends.
Running A Data Consistency Check
To perform a consistency check:
1.Press <Ctrl> <N> to access the VD Mgmt menu screen.
2.Press the
3.Press <F2> to display the menu of available actions.
4.Press the
5.Press the
6.Select Start and press <Enter> to run a Consistency Check.
43