Foreign Configuration Not Found In <Ctrl> <R> Error Message

Error Message:

The foreign configuration message is present during POST but no

 

foreign configurations are present in the foreign view page in

 

<Ctrl> <R>. All virtual disks are in an optimal state.

Corrective

Corrective Action: Ensure all your PDs are present and all VDs are in optimal state. Clear the

Action:

foreign configuration using <Ctrl> <R> or Dell OpenManage Server Administrator Storage

 

Management.

 

CAUTION: The physical disk goes to Ready state when you clear the foreign configuration.

 

If you insert a physical disk that was previously a member of a virtual disk in the system, and

 

that disk’s previous location has been taken by a replacement disk through a rebuild, you must

 

manually remove the foreign configuration flag of the newly inserted disk.

Previous Configuration Cleared Or Missing Error Message

Error Message:

Previous configuration(s) cleared or missing. Importing

 

configuration created on XX/XX XX.XX. Press any key to

 

continue, or ’C’ to load the configuration utility.

Probable Cause:

The message indicates that the controller and physical disks have different configurations.

Corrective

You can use the BIOS Configuration Utility (<Ctrl> <R>) to clear the foreign configuration.

Action:

 

Invalid SAS Topology Detected Error Message

Error Message:

Invalid SAS topology detected. Please check your cable

 

configurations, repair the problem, and restart your system.

Probable Cause:

The SAS cables for your system are improperly connected.

Corrective

Check the cable connections and fix problems if any. Restart the system.

Action:

 

Multibit ECC Errors Detected Error Messages

Error Message:

NOTE: The following error is specific to the PERC H710 controller only.

 

Multibit ECC errors were detected on the RAID controller. If you continue, data corruption can occur. Contact technical support to resolve this issue. Press 'X' to continue or else power off the system, replace the controller and reboot.

Or

Multibit ECC errors were detected on the RAID controller. The DIMM on the controller needs replacement. If you continue, data corruption can occur. Press 'X' to continue or else power off the system, replace the DIMM module, and reboot. If you have replaced the DIMM please press 'X' to continue.

76

Page 76
Image 76
Dell H710P, H310, H810 Foreign Configuration Not Found In Ctrl R Error Message, Invalid SAS Topology Detected Error Message

H310, H710, H710P, H810 specifications

Dell offers a range of storage controller technologies, notably the H810, H710, H710P, and H310, which cater to different enterprise needs. These controllers are designed to support various storage configurations, enhancing overall system performance and reliability.

The Dell H810 is a high-performance PCIe 3.0 RAID controller that supports up to eight internal drives and is particularly suited for demanding workloads. It features advanced RAID levels including RAID 0, 1, 5, 6, 10, 50, and 60, providing flexibility for various data protection strategies. The H810 also supports up to 32TB of storage capacity, making it suitable for environments that require substantial data management capabilities.

The H710 is another powerful RAID controller, widely recognized for its balance of performance and cost-efficiency. It features 1GB of cache memory, which aids in accelerating read and write operations. The H710 supports the same RAID levels as the H810 and allows for up to 512MB of non-volatile memory. This ensures data integrity even in the event of a power failure, making it reliable for critical applications.

The H710P is an enhanced version of the H710, with a significant upgrade in its cache capabilities. It offers 2GB of battery-backed cache memory, further enhancing data processing speeds and improving responsiveness. The H710P is ideal for intensive workloads and virtualization, where rapid access to data is essential. This controller also includes features such as RAID storage pooling, intelligent data tiering, and support for multiple virtual disks.

Finally, the H310 is a cost-effective option for small to medium-sized businesses or those with less demanding storage requirements. It offers similar RAID support as the higher-end controllers but operates with a simpler architecture. The H310 features 512MB of cache, providing sufficient performance for regular workloads without the additional complexities of more advanced controllers.

In summary, Dell's H810, H710, H710P, and H310 storage controllers each serve distinct purposes, providing various features, technologies, and performance characteristics tailored to different business needs. From high-capacity storage solutions to user-friendly setups, Dell’s offerings ensure that organizations can efficiently manage their data storage requirements.