Environmental

Operating

Non-Operating

Specifications

 

 

 

Ambient Temperature

0° C to 50° C

-40° C to 70° C

Relative Humidity (1)

5% to 95%

5% to 95%

Altitude

-1000 to 10,000 ft

-1000 to 40,000 ft

-305m to 3048m

-305m to 12195m

 

 

 

 

Shock (2)

10g

60g

 

 

 

(1)Non-condensing with maximum gradient of 10% per hour.

(2)Half-sine wave shock pulses at 2ms.

Physical Specifications

Carrier

Receiving Frame

Receiving Frame

(Excluding Front Bezel)

(Including Front Bezel)

 

 

 

 

Height

1.07” (27.2mm)

1.60” (40.6mm)

1.62” (41.1mm)

 

 

 

 

Width

4.34” (110.2mm)

5.75” (146.1mm)

5.81” (147.6mm)

Depth

7.54” (191.5mm)

7.88” (200.2mm)

8.08” (205.2mm)

 

 

 

 

Weight

0.9lb (0.41kg)

 

1.9lb (0.86kg) (1)

(1) With carrier removed.

Chassis Reliability/Maintainability

MTBF (at 30° C)

600,000 Hours

 

 

 

MTTR

5 minutes

 

 

 

Preventive

None

Maintenance

 

 

 

 

 

 

 

 

Insertion Rating

 

 

 

 

 

50,000

 

 

 

 

 

Electrical Specifications

Input

+5V

9mA

 

 

 

+12V

20mA

 

 

 

Cooling (Total for 1 Fan)

4.6 CFM

StorCase Technology, Inc.

DX115 for Backup User's Guide - Rev. A01

Image 23
Contents Data Express DX115 for Backup Fax 714 Part No. D89-0000-0306 A01 JuneStorCase Technology, Inc Newhope Street Fountain Valley, CA Duration of Warranty Limited WarrantyFree Technical Support Warranty Claim RequirementsDeclaration of Conformity Table of Contents Sata 3Gbps DX115 Receiving Frame and Carrier List of FiguresReceiving Frame Device Carrier Packaging InformationSerial Numbers Package Contents Sata 3Gbps DX115 Receiving Frame and Carrier General DescriptionFront Panel Front PanelDrive Ready Blue Power Switch contdError Red Fan Receiving Frame Rear PanelPreparation Installing the Drive into the Drive CarrierDrive Installation Assembly Drive Cover Installation Receiving Frame Mounting Holes Installing the Receiving FrameDrive Activity LED Drive Hot Swap Data Backup and Restoration Removing the Cooling Fan Replacing the Cooling FanAppendices Specifications and dimensions below are for reference only Appendix a Specifications/DimensionsReceiving Frame with Carrier Installed Carrying Case Appendix B Optional AccessoriesReaders Comments Business Reply Mail