SMC Networks SMCRPU14 manual Power Cord Set

Page 10

COMPLIANCES

France and Peru only

This unit cannot be powered from ITsupplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary con- nection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Power Cord Set

U.S.A. and Canada

The cord set must be UL-approved and CSA certified.

 

 

 

The minimum specifications for the flexible cord are:

 

- No. 18 AWG - not longer than 2 meters, or 16 AWG.

 

- Type SV or SJ

 

- 3-conductor

 

 

 

The cord set must have a rated current capacity of at least 10 A.

 

 

 

The attachment plug must be an earth-grounding type with NEMA 5-15P

 

(15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

 

 

Denmark

The supply plug must comply with Section 107-2-D1, Standard DK2-1a

 

or DK2-5a.

 

 

Switzerland

The supply plug must comply with SEV/ASE 1011.

 

 

U.K.

The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with

 

a 5 A fuse which complies with BS1362.

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of type

 

HO3VVF3GO.75 (minimum).

 

 

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”).

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of type

 

HO3VVF3GO.75 (minimum).

 

 

 

IEC-320 receptacle.

 

 

Veuillez lire à fond l'information de la sécurité suivante avant d'installer le RPU:

AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié.

Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).

vi

Image 10
Contents Redundant Power Unit Page Redundant Power Unit User Guide Trademarks Limited Warranty Limited Warranty Industry Canada Class B CompliancesFCC Class B Japan Vcci Class BEC Conformance Declaration Class B Australia AS/NZS 3548 1995 Class B Power Cord Set Vii Viii Compliances Purpose Environmental StatementAudience Table of Contents Table of Contents Features and Benefits Chapter About the Redundant Power UnitOverview Front and Rear Panels LEDsPort Status LEDs Page Installation Chapter Installing Redundant Power UnitSelecting a Site Package Contents Equipment ChecklistOptional Rack-Mounting Equipment Mounting Rack MountingAttaching the Brackets Montage Rack Mounting German Connecting Switches to the RPU Desktop or Shelf MountingPower Receptacle Connecting the RPU in a Stack Appendix a Troubleshooting Diagnosing RPU IndicatorsPower and Cooling Problems Flashing YellowAppendix B. Specifications Physical CharacteristicsCompliances Safety Page Index RPUIndex Page Internet