SMC Networks SMCRPU14 manual EC Conformance Declaration Class B

Page 8

COMPLIANCES

EC Conformance Declaration - Class B

SMC contact for these products in Europe is:

SMC Networks Europe, Edificio Conata II,

Calle Fructuós Gelabert 6-8, 2o, 4a,

08970 - Sant Joan Despí, Barcelona, Spain.

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

• Limit class B according to EN 55022:1998

 

• Limit class A for harmonic current emission according to

 

EN 61000-3-2/1995

 

• Limitation of voltage fluctuation and flicker in low-voltage supply

 

system according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

 

• Electrostatic Discharge according to EN 61000-4-2:1995

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to EN 61000-4-3:1996

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/

 

DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency

 

fields: EN 61000-4-6:1996 (0.15 - 80 MHz with

 

1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

• EN 60950 :2000

iv

Image 8
Contents Redundant Power Unit Page Redundant Power Unit User Guide Trademarks Limited Warranty Limited Warranty Compliances FCC Class BIndustry Canada Class B Japan Vcci Class BEC Conformance Declaration Class B Australia AS/NZS 3548 1995 Class B Power Cord Set Vii Viii Compliances Audience Environmental StatementPurpose Table of Contents Table of Contents Overview Chapter About the Redundant Power UnitFeatures and Benefits Front and Rear Panels LEDsPort Status LEDs Page Selecting a Site Chapter Installing Redundant Power UnitInstallation Optional Rack-Mounting Equipment Equipment ChecklistPackage Contents Mounting Rack MountingAttaching the Brackets Montage Rack Mounting German Connecting Switches to the RPU Desktop or Shelf MountingPower Receptacle Connecting the RPU in a Stack Appendix a Troubleshooting Diagnosing RPU IndicatorsPower and Cooling Problems Flashing YellowAppendix B. Specifications Physical CharacteristicsCompliances Safety Page Index RPUIndex Page Internet