TROUBLESHOOTING
| Table | |
|
|
|
Symptom |
| Action |
|
|
|
Stack Link LED is |
| • The uplink/downlink has failed. |
Flashing Green/Amber |
| • Check that the stacking cables are connected properly. |
|
| |
|
| Replace the cable if necessary. |
|
| • Power cycle the switch to try and clear the condition. |
|
|
|
Link LED is Off |
| • Verify that the switch and attached device are powered |
|
| on. |
|
| • Be sure the cable is plugged into both the switch and |
|
| corresponding device. |
|
| • Verify that the proper cable type is used and its length |
|
| does not exceed specified limits. |
|
| • Check the adapter on the attached device and cable |
|
| connections for possible defects. Replace the defective |
|
| adapter or cable if necessary. |
|
|
|
Power and Cooling Problems
If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective.
Installation