Xantech HD44CC5 installation instructions RS232 Command Structure, Name Command Return Remarks

Page 4

RS232 COMMAND STRUCTURE

Where:

{CR#} – Carriage Return (0x0D)

{z#} - Zone Number. Range is 1..4 (1..16 if expanded) {s#} - Source Input Number. Range is 1..4

{0/1} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.

 

NAME

 

 

COMMAND

 

 

RETURN

 

 

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

!{z#}PR01+

 

 

 

 

To turn on Zone 2: !2PR1+ or !02PR1+ or

 

Zone Power

 

 

OK{CR}

 

!2PR01+ or !02PR01+

 

 

 

 

 

 

 

 

!{z#}PR00+

 

ERROR{CR}

 

To turn off Zone1: !1PR0+ or !01PR0+ or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

!1PR00+ or !01PR00+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone Power

 

!{z#}PT+

 

OK{CR}

 

 

 

Toggle

 

 

ERROR{CR}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Zones Off

 

!EO+

 

OK{CR}

 

Turns all the zones off.

 

 

 

ERROR{CR}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Zones On

 

!EA+

 

OK{CR}

 

Turns all the zones on.

 

 

 

ERROR{CR}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone Restore All

 

!RF+

 

OK{CR}

 

Restore all the Zone-to-Source routing to the

 

 

 

ERROR{CR}

 

current selection: !RF+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input (Source)

 

!{z#}SS{s#}+

 

OK{CR}

 

To set Zone 1 to Source Input 4: !1SS4+

 

Select

 

 

ERROR{CR}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ping Expansion

 

!RP+

 

OK{CR}

 

Request that any unit connected to the expansion

 

Port

 

 

ERROR{CR}

 

port respond with a ping.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return Ping to

 

!SP+

+

 

 

Returns a +. Meant for inter-expansion box

 

Xantech port

 

 

 

communications.

 

 

 

 

 

 

 

 

 

 

08905071B

- 4 -

Image 4
Contents Specifications DescriptionDetail Overview Source LOOP-THROUGH Connection Source InputsRS232 Serial Commands IR ReceiverPlug Circuit IR BUS, Emitter PortRS232 Command Structure Name Command Return RemarksRS232 Queries Name Query Return Example ExplanationAC Power Input Address DIP SwitchRS232 Expansion AddrCAT5 Zone Output Coaxial Zone OutputQuick Installation HD44CC5 and HDRXSG01 RC68+ IR Commands RC68+ should be set to Group Code C0Advance Installation 08905071B Common Problems and Troubleshooting This page intentionally left blank This page intentionally left blank This page intentionally left blank Xantech Limited Warranty