Xantech RS2321X8 installation instructions Connecting to the MRC88 Controller

Page 4

Page 4

RS2321X8 Serial Router

5. Connect Power using a 12VDC Power Supply (Xantech Model 781RG or 782-00).

Figure 2: Connecting to the MRC88 Controller

ENABLING THE RS2321X8 ROUTER:

(Drag450MRC Version 3.0.build 77 or higher) Note: Refer to Figure 3 for Software Configuration.

1.Start DragMRC Software and open a new or existing MRC88 project.

2.Click on the RS232 Settings Tab.

3.Click on the Use Router check box under the Com Port or Expansion Port RS232 Sections. You can now configure each of the 8 ports of the router individually to communicate with 8 different Serial devices.

CONFIGURING PORT SETTINGS:

1.Selecting Router Port: Click on drop-down menu and select the Router Port to configure.

2.Configuring Port: Click on the drop-down menus for Baud Rate, Data Bits, Parity, and Stop Bit and set to

Manufactures specification for the Serial Device connected to the selected Router Port. Note: Please refer to the devices manual for the proper Port Configurations or consult directly with the Manufacturer.

1.Process RS232 Input: Click on this check box for bi-directional devices or any device that will

return strings to the MRC88’s Serial Port. Note: If this port is not selected, the MRC88 will ignore any commands being sent back from the external device.

2.Repeat this process for all Router Ports being used.

3.Default Port Selection: If there is a main RS232 Serial Device that might randomly send strings back to the MRC88 (Xantech XDT Dual Tuner, Lighting or Temperature Controller etc…) you can select the port on the router this device is connected to and the Router will automatically always return to this port after any selection is made to another output port.

© 2005 Xantech Corporation

Image 4
Contents Features Table of ContentsIntroduction Installation Power Wiring SpecificationsOutput Serial Wiring Configuration and Control MRC88 IntegrationConnecting to the MRC88 Controller Smartpad LCD Integration MRC88 Dragon-IR SoftwareConnecting to the SmartPad LCD Controller STAND-ALONE Operation INFRA-RED Port Switching SmartPad LCD Dragon-IR SoftwareRC68+ Programmer Selecting RC68+ Palette RS2321X8 Wired in IR ‘Standalone’ Application RS2321X8 Serial Router SmartPad LCD Dragon Programming for Example #2 Connector Pinout Diagrams Appendix Panel ConnectionsBaud Rate Selector Switch Source Input Select JumperRS2321X8 Serial Router Xantech Corporation Xantech Corporation