3.10Environmental specifications
This section provides the temperature, humidity, shock, and vibration specifications for Momentus drives.
3.10.1Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Above 1000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
Operating: | 0°C to 60°C (32°F to 140°F) |
|
|
Nonoperating: | |
|
|
3.10.2Temperature gradient
Operating | 20°C per hour (68°F per hour max), without condensation |
|
|
Nonoperating | 35°C per hour (95°F per hour max), without condensation |
|
|
3.10.3Relative humidity
Operating | 5% to 95% noncondensing (30% per hour max) |
|
|
Nonoperating | 5% to 95% noncondensing (30% per hour max) |
|
|
3.10.4Wet bulb temperature
Operating | 37.7°C (99.8°F max) |
|
|
Nonoperating | 40°C (104°F max) |
|
|
3.10.5Altitude
Operating | |
|
|
Nonoperating | |
|
|
Momentus Product Manual, Rev. B | 13 |