2.11Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 6: | Radio frequency environments |
|
| |
|
|
|
|
|
Test |
| Description | Performance level | Reference standard |
|
|
|
| |
Electrostatic discharge | Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV | B | EN | |
|
|
|
| |
Radiated RF immunity | 80 to 1,000 MHz, 3 V/m, | A | EN | |
|
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
|
| 900 MHz, 3 V/m, 50% pulse modulation @ |
|
|
|
| 200 Hz |
|
|
|
|
|
| |
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on external I/ | B | EN | |
|
| O |
|
|
|
|
|
| |
Surge immunity | ± 1 kV differential, ± 2 kV common, AC | B | EN | |
|
| mains |
|
|
|
|
|
| |
Conducted RF immunity | 150 kHz to 80 MHz, 3 Vrms, 80% AM with | A | EN | |
|
| 1 kHz sine |
|
|
|
|
|
| |
Voltage dips, interrupts | 0% open, 5 seconds | C | EN | |
|
| 0% short, 5 seconds | C |
|
|
| 40%, 0.10 seconds | C |
|
|
| 70%, 0.01 seconds | B |
|
|
|
|
|
|
2.12 | Reliability |
|
|
| |
Nonrecoverable read errors | 1 per 1014 bits read, max | |
Annualized Failure Rate (AFR) | 0.34% (nominal power, 25°C ambient temperature) | |
|
| |
Contact | 50,000 cycles | |
|
| (at nominal voltage and temperature, with 60 cycles per hour and a 50% duty |
|
| cycle) |
|
| |
Service Life | 5 years | |
|
|
|
Warranty |
| 5 years on distribution units. |
|
| To determine the warranty for a specific drive, use a web browser to access the |
|
| following web page: |
|
| www.seagate.com/support/service/ |
|
| From this page, click on the “Verify Your Warranty” link. You will be asked to pro- |
|
| vide the drive serial number, model number (or part number) and country of pur- |
|
| chase. The system will display the warranty information for your drive. |
|
| |
Preventive maintenance | None required. | |
|
|
|
18 | Barracuda 7200.8 Serial ATA Product Manual, Rev. F |