4.2.1Identify Device command

The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte (256 word) block of data, whose contents are as shown in the following table.

Word

ATA specification

Value

 

 

 

0

General configuration information bit-significant information

0040h

 

Bit 15: 0 = ATA device

 

 

Bit 7: 1 = removable media

 

 

Bit 6: 1 = non-removable/fixed device

 

 

 

 

10–19

Serial number: (20 ASCII characters)

Serial number

 

 

 

23–26

Firmware revision (8 ASCII character string)

Firmware revision

 

 

 

27–46

Drive model number:

Model number

 

(40 ASCII characters, padded with blanks to end of string)

 

 

 

 

47

Bits 7-0: Maximum number of sectors transferred per interrupt on

8010h

Read Multiple/ Write Multiple commands

 

 

49

Capabilities

2B00h

 

Bit 13: 1= Standby timer values specified in ATA-7 are supported

 

 

Bit 11: 1= IORDY supported

 

 

Bit 10: 0= IORDY may not be disabled

 

 

Bit 9 : 1= LBA supported

 

 

Bit 8 : 1= DMA supported

 

53

Bit 2: 1= the fields reported in word 88 are valid

0007h

 

Bit 1: 1= the fields reported in words (70:64) are valid

 

 

 

 

59

Bit 8: 1= Multiple sector setting is valid

0110h

 

Bits 7-0: Current setting for number of sectors transferred during a

 

 

Read/Write Multiple command

 

60–61

Total number of user-addressable LBA sectors available

37E3E40h (30GB)

 

 

6FC7C80h (60GB)

63

Bit 10: 1= Multiword DMA mode 2 is selected

xxx7h

 

0= Multiword DMA mode 2 is not selected

 

 

Bit 9: 1= Multiword DMA mode 1 is selected

 

 

0= Multiword DMA mode 1 is not selected

 

 

Bit 8: 1= Multiword DMA mode 0 is selected

 

 

0= Multiword DMA mode 0 is not selected

 

 

Bit 2: 1= Multiword DMA mode 2 and below are supported

 

 

Bit 1: 1= Multiword DMA mode 1 and below are supported

 

 

Bit 0: 1= Multiword DMA mode 0 is supported

 

64

Bits 7-0: PIO modes supported

0003h

 

 

 

65

Minimum Multiword DMA transfer cycle time per word

0078h

 

Bits 15-0: Cycle time in nanoseconds

 

66

Recommended Multiword DMA transfer cycle time

0078h

 

Bits 15-0: Cycle time in nanoseconds

 

67

Minimum PIO transfer cycle time without flow control

0078h

 

Bits 15-0: Cycle time in nanoseconds

 

68

Minimum PIO transfer cycle time with IORDY flow control

0078h

 

Bits 15-0: Cycle time in nanoseconds

 

Lyrion Series IDE Product Manual, Rev. E

27

Image 33
Contents ST760211DE ST730212DE Lyrion Series IDERevision Date Revision historyContents Lyrion Series IDE Product Manual, Rev. E List of Figures Lyrion Series IDE Product Manual, Rev. E Lyrion Series IDE interface disc drive IntroductionDrive care DisclaimerSpecifications Drive specificationsDrive specification ST760211DE ST730212DE OverviewLBA mode addressing Default logical geometryFormatted capacity Model Cylinders Heads SectorsTechnology Specification Physical characteristicsRecording and interface technology Time to readyPower specifications DC power Power Consumption at Average WTypical current profile Voltage tolerance Voltage tolerance including noise Conducted noiseActive mode Power-management modesStandby/Sleep mode Power modes Heads Spindle BufferEnvironmental specifications Operating shock ShockNonoperating shock VibrationOperating random vibration Operating sweep sine vibrationOperating random vibration profile Nonoperating sweep sine vibrationNonoperating random vibration Nonoperating random vibration profileCorrosive environment Electromagnetic immunity AcousticsDrive level acoustics Electromagnetic immunityReliability Measurement type SpecificationAgency certification Safety certificationElectromagnetic compatibility Korean RRLFCC verification China Restriction of Hazardous Substances RoHS DirectivePage Handling and static discharge precautions Configuring and mounting the drivePage Lyrion Series mechanical dimensions-top, side and end view Drive installationMounting considerations Lyrion Series FPC dimensionsConnector interface signals and connector pins Way ZIF IDE interface connector signalsInterface description Iordy Supported ATA commands Supported commandsCommand Name Command Op-Code Command Type Supported commands Word ATA specification Value Identify Device commandLyrion Series IDE Product Manual, Rev. E Set Features command Features register valuesFeature Description Lyrion Series IDE Product Manual, Rev. E Internet Seagate Technology support servicesPresales Support Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Publication feedback survey Lyrion Series IDE Product Manual, Rev. E Index Page Page Seagate Technology LLC