4.5.1Caching write data

Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command.

If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made avail- able for future read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for subsequent Read commands.

If the number of write data logical blocks exceed the size of the segment being written into, when the end of the segment is reached, the data is written into the beginning of the same cache segment, overwriting the data that was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.

If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the medium, and Good status has already been returned, a deferred error will be gen- erated.

The Synchronize Cache command may be used to force the drive to write all cached write data to the medium. Upon completion of a Synchronize Cache command, all data received from previous write commands will have been written to the medium.

Table 10.3.2.1 shows the mode default settings for the drive.

4.5.2Prefetch operation

If the Prefetch feature is enabled, data in contiguous logical blocks on the disk immediately beyond that which was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buf- fer to the host on subsequent Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.

To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0 enables prefetch.

The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).

When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not likely to occur.

Cheetah 15K.7 SAS Product Manual, Rev. A

11

Image 17
Contents Standard models Self-Encrypting Drive models Cheetah 15K.7 SASPage Contents Installation Defect and error managementAbout self-encrypting drives Interface requirementsSeagate Technology support services Cheetah 15K.7 SAS Product Manual, Rev. a Model Number Capacity Self-Encrypting Drive SED ScopeStandards Standards, compliance and reference documentsElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS ComplianceReference documents General description Performance Standard featuresMedia description Reliability Factory-installed optionsFormatted capacities Programmable drive capacityInternal drive characteristics Performance characteristicsAccess time Seek timeStart/stop time Format command execution time minutesGeneral performance characteristics Cache operation Prefetch/multi-segmented cache controlPrefetch operation Caching write dataError rates Reliability specificationsRecoverable Errors Unrecoverable ErrorsSeek errors Reliability and serviceInterface errors Preventive maintenanceControlling S.M.A.R.T 4 S.M.A.R.TPerformance impact MillisecondsDetermining rate Reporting controlPredictive failures Thermal monitorState of the drive prior to testing Temperature Log Page 0Dh Parameter Code DescriptionDrive Self Test DST DST failure definitionShort and extended tests Invoking DSTShort test Function Code 001b Extended test Function Code 010bAbort Product warrantyShipping Product repair and return informationDC power requirements Physical/electrical specificationsAC power requirements ST3600057SS ST3600957SS Gbit mode Amps 600 GB DC power requirementsST3450857SS ST3450757SS Gbit mode Amps 450 GB DC power requirementsST3300657SS ST3300557SS Gbit mode Amps 300 GB DC power requirementsCurrent profiles Power sequencingConducted noise immunity Typical 600GB current profiles Typical 300GB current profiles ST3600057SS model Power dissipationST3450857SS model ST3300657SS model TemperatureEnvironmental limits Effective altitude sea level Relative humidityShock and vibration ShockPackage size Packaged/product weight Drop height Recommended mounting VibrationAcoustics Air cleanlinessCorrosive environment RoHS compliance statementPhysical dimensions Mechanical specificationsAdmin SP Controlled accessAbout self-encrypting drives Data encryptionRandom number generator RNG Authenticated firmware downloadDrive locking Data bandsSupported commands Power requirementsDrive error recovery procedures Defect and error managementDrive internal defects/errors Page Background Media Scan SAS system errorsIdle Read After Write Media Pre-ScanDeferred Auto-Reallocation Cooling InstallationDrive orientation Grounding Drive mountingInterface requirements SAS featuresCommands supported by Cheetah 15K.6 SAS family drives Scsi commands supportedCommand name Command code Supported Dual port supportCommands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Commands supported by Cheetah 15K.6 SAS family drives Cheetah 15K.7 inquiry data Bytes Data hex Inquiry dataMode Sense data Mode Pages 10.3.2.1 ST3600057SS and ST3600957SS Mode Sense dataDEF CHG Mode Data Header Block Descriptor Mode Pages 10.3.2.2 ST3450857SS and ST3450757SS Mode Sense dataDEF CHG Read Capacity Data Buffer C D E F Mode Pages 10.3.2.3 ST3300657SS and ST3300557SS Mode Sense dataMiscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical interface SAS physical interfaceDatum B Connector requirements Physical characteristicsElectrical description Pin Signal name Signal typePin descriptions SAS pin descriptionsPower Signal characteristicsSAS transmitters and receivers Ready LED OutLED drive signal SAS-2 Specification complianceDifferential signals General interface characteristicsTechnical Support Seagate Technology support servicesPresales Support Data Recovery Services Call CenterToll-freeDirect dialFAX Warranty ServiceData Recovery Services Authorized Service Centers Cheetah 15K.7 SAS Product Manual, Rev. a Numerics IndexPage SAS Smart