Seagate ST3400755FC, ST3300955FC manual Reference documents, Ncits TR-19

Page 15

2.3Reference documents

Cheetah NS FC Installation Guide

SCSI Commands Reference Manual

Fibre Channel Interface Manual

ANSI Fibre Channel Documents X3.230-1994

X3.297.1997

X3.303.1998

X3.272-1996

X3.269-1996

NCITS TR-19

NCITS TR-20 SFF-8045 SFF-8067

Seagate part number: 100457517

Seagate part number: 100293068

Seagate part number: 100293070

FC Physical and Signaling Interface (FC-PH)

FC-PH-2 Fibre Channel Physical and Signaling Interface-2 FC-PH-3 Fibre Channel Physical and Signaling Interface-3 FC Arbitrated Loop (FC-AL)

Fibre Channel Protocol for SCSI (FCP) Private Loop SCSI Direct Attach (PLDA) Fabric Loop Attachment (FC-FLA)

Specification for 40-pin SCA-2 Connector with Parallel Selection Specification for 40-pin SCA-2 Connector with Bidirectional Enclosure Services Interface

ANSI Small Computer System Interface (SCSI) Documents

X3.131-1994

(SCSI-2)

 

X3.270-1996

(SCSI-3) Architecture Model

NCITS 305-199X

(SCSI-3) Enclosure Services

Specification for Acoustic Test Requirement and Procedures

 

 

Seagate part number: 30553-001

Package Test Specification

Seagate P/N 30190-001

(under 100 lb.)

Package Test Specification

Seagate P/N 30191-001

(over 100 lb.)

In case of conflict between this document and any referenced document, this document takes precedence.

Cheetah NS FC Product Manual, Rev. A

5

Image 15
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. a Cheetah NS FC Product Manual, Rev. a Contents Defect and error management InstallationInterface requirements Seagate Technology support services Cheetah NS FC Product Manual, Rev. a List of Figures Page Scope Cheetah NS FC Product Manual, Rev. a Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. a General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesUser-installed accessories Factory-installed optionsSeek performance Performance characteristicsInternal drive characteristics Access timeFormat command execution time minutes General performance characteristicsStart/stop time Prefetch/multi-segmented cache control Cache operationCaching write data Prefetch operation Unrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingParameter Code Description Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah NS FC Product Manual, Rev. a DC power requirements for ST3400755FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. a Random 8 Block Reads Power dissipationST3400755 CURRENT/POWER vs Throughput FC 4GB ST3400755FCST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBTemperature Environmental limitsRelative humidity Shock Package size Packaged/product weight Drop heightEffective altitude sea level Shock and vibrationRecommended mounting Corrosive environment Air cleanlinessVibration AcousticsChina Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. a Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.87 FC-AL system errors Background Media ScanMedia Pre-Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. a Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. a Temperature page 0Dh Mode Sense data Inquiry dataCheetah NS FC inquiry data Bytes Data hex Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Technical Support Seagate Technology support servicesInternet Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi SEL ID See also cooling
Related manuals
Manual 90 pages 1.15 Kb