Seagate ST3400755FC, ST3300955FC manual Defect and error management, Drive internal defects/errors

Page 47

7.0Defect and error management

Seagate continues to use innovative technologies to manage defects and errors. These technologies are designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation.

SCSI defect and error management involves drive internal defect/error management and FC system error con- siderations (errors in communications between the initiator and the drive). In addition, Seagate provides the following technologies used to increase data integrity and drive reliability:

Background Media Scan (see Section 7.4)

Media Pre-Scan (see Section 7.5)

Deferred Auto-Reallocation (see Section 7.6)

Idle Read After Write (see Section 7.7)

The read error rates and specified storage capacities are not dependent on host (initiator) defect management routines.

7.1Drive internal defects/errors

During the initial drive format operation at the factory, media defects are identified, tagged as being unusable, and their locations recorded on the drive primary defects list (referred to as the “P’ list and also as the ETF defect list). At factory format time, these known defects are also reallocated, that is, reassigned to a new place on the medium and the location listed in the defects reallocation table. The “P” list is not altered after factory formatting. Locations of defects found and reallocated during error recovery procedures after drive shipment are listed in the “G” list (defects growth list). The “P” and “G” lists may be referenced by the initiator using the Read Defect Data command.

Details of the SCSI commands supported by the drive are described in the Fibre Channel Interface Manual. Also, more information on the drive Error Recovery philosophy is presented in the Fibre Channel Interface Manual.

7.2Drive error recovery procedures

When an error occurs during drive operation, the drive, if programmed to do so, performs error recovery proce- dures to attempt to recover the data. The error recovery procedures used depend on the options previously set in the Error Recovery Parameters mode page. Error recovery and defect management may involve using sev- eral SCSI commands described in the Fibre Channel Interface Manual. The drive implements selectable error recovery time limits required in video applications.

The error recovery scheme supported by the drive provides a way to control the total error recovery time for the entire command in addition to controlling the recovery level for a single LBA. The total amount of time spent in error recovery for a command can be limited using the Recovery Time Limit bytes in the Error Recovery mode page. The total amount of time spent in error recovery for a single LBA can be limited using the Read Retry Count or Write Retry Count bytes in the Error Recovery mode page.

Cheetah NS FC Product Manual, Rev. A

37

Image 47
Contents ST3400755FC ST3300955FC Cheetah NS FCPage Cheetah NS FC Product Manual, Rev. a Cheetah NS FC Product Manual, Rev. a Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah NS FC Product Manual, Rev. a List of Figures Page Scope Cheetah NS FC Product Manual, Rev. a Electromagnetic susceptibility Standards, compliance and reference documentsStandards Electromagnetic compatibilityCompliance Ncits TR-19 Reference documentsCheetah NS FC Product Manual, Rev. a General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesUser-installed accessories Factory-installed optionsSeek performance Performance characteristicsInternal drive characteristics Access timeStart/stop time Format command execution time minutesGeneral performance characteristics Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Unrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingParameter Code Description Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah NS FC Product Manual, Rev. a DC power requirements for ST3400755FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST3300955FC model Gbit Amps General DC power requirement notesConducted noise immunity Power sequencingCurrent profiles Cheetah NS FC Product Manual, Rev. a Random 8 Block Reads Power dissipationST3400755 CURRENT/POWER vs Throughput FC 4GB ST3400755FCST3300955FC ST3300955 CURRENT/POWER vs Throughput FC 4GBRelative humidity TemperatureEnvironmental limits Shock Package size Packaged/product weight Drop heightEffective altitude sea level Shock and vibrationRecommended mounting Corrosive environment Air cleanlinessVibration Acoustics China Restriction of Hazardous Substances RoHS Directive X表示该部件(于同类物品程度上)所含的危险和有毒物质中国RoHS MCV标准所定义的门槛值。Mounting configuration dimensions Mechanical specificationsCheetah NS FC Product Manual, Rev. a Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.87 Media Pre-Scan FC-AL system errorsBackground Media Scan Idle Read After Write Deferred Auto-ReallocationCooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah NS FC Product Manual, Rev. a Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah NS FC Product Manual, Rev. a Temperature page 0Dh Cheetah NS FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Sense 10 Byte Header Data Mode Data Header Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Fault LED Out PowerMotor start controls Enable port bypass signalsActive LED Out 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESIHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Technical Support Seagate Technology support servicesInternet Presales SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Numerics IndexFAN Flogi Plogi SEL ID See also cooling
Related manuals
Manual 90 pages 1.15 Kb