Seagate ST373453LC manual Installation, Drive ID/option selection, Drive orientation, Cooling

Page 51

8.0Installation

Cheetah 15K.5 FC disc drive installation is a plug-and-play process. There are no jumpers, switches, or termi- nators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC- SCA)no cables are required. See Section 9.5 for additional information about this connector.

Use the FC-AL interface to select drive ID and all option configurations for devices on the loop.

If multiple devices are on the same FC-AL and physical addresses are used, set the device selection IDs (SEL IDs) on the backpanel so that no two devices have the same selection ID. This is called the hard assigned arbi- trated loop physical address (AL_PA). There are 125 AL_PAs available (see Table 26). If you set the AL_PA on the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selec- tion IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address auto- matically.

Loop initialization is the process used to verify or obtain an address. The loop initialization process is per- formed when power is applied to the drive, when a device is added or removed from the Fibre Channel loop, or when a device times out attempting to win arbitration.

Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to the drive, recycle the drive power to activate the new settings.

It is not necessary to low-level format this drive. The drive is shipped from the factory low-level formatted in 512-byte logical blocks. You need to reformat the drive only if you want to select a different logical block size.

8.1Drive ID/option selection

All drive options are made through the interface connector (J1). Table 23 provides the pin descriptions for the 40-pin Fibre Channel single connector (J1).

8.2Drive orientation

The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two pre- ferred mounting orientations.

8.3Cooling

The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Section 6.4.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in Section 6.4.1.

Cheetah 15K.5 FC Product Manual, Rev. F

43

Image 51
Contents ST3300655FC ST3146855FC ST373455FC Cheetah 15K.5 FCPage Contents Defect and error management InstallationInterface requirements Seagate Technology support services Cheetah 15K.5 FC Product Manual, Rev. F List of Figures Page Scope Cheetah 15K.5 FC Product Manual, Rev. F Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-20 Reference documentsCheetah 15K.5 FC Product Manual, Rev. F General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesFactory-installed accessories Factory-installed optionsUser-installed accessories Access time Performance characteristicsInternal drive characteristics Seek performance characteristicsPrefetch/multi-segmented cache control Format command execution time minutesGeneral performance characteristics Start/stop timeCaching write data Cache operationPrefetch operation Unrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingParameter Code Description Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah 15K.5 FC Product Manual, Rev. F DC power requirements for ST3300655FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST373455FC model Gbit Amps DC power requirements for ST3146855FC model Gbit AmpsCurrent profiles General DC power requirement notesPower sequencing Conducted noise immunityTypical ST3300655FC drive, 4 Gbit, +12V current profile Typical ST3146855FC drive, 4 Gbit, +12V current profile Typical ST373455FC drive, 4 Gbit, +12V current profile ST3300655FC Power dissipationST3146855FC ST3146855FC CURRENT/POWER vs Throughput FC 4GBST373455FC TemperatureST373455FC CURRENT/POWER vs Throughput FC 4GB Environmental limitsShock Relative humidityEffective altitude sea level Shock and vibrationPackage size Packaged/product weight Drop height Recommended mounting Corrosive environment Air cleanlinessVibration AcousticsRoHS compliance statement Mounting configuration dimensions Mechanical specificationsCheetah 15K.5 FC Product Manual, Rev. F Defect and error management Drive internal defects/errorsDrive error recovery procedures Page Background Media Scan FC-AL system errorsMedia Pre-Scan Deferred Auto-ReallocationIdle Read After Write Cooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah 15K.5 FC Product Manual, Rev. F Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah 15K.5 FC Product Manual, Rev. F Temperature page 0Dh Mode Sense data Inquiry dataCheetah 15K.5 FC inquiry data Bytes Data hex Page Mmode Sense 10 Byte Header Data Mode Sense 10 Byte Header Data 00 ae 00 10 00 00 00 08 08 8b b9 98 00 00 02 Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah 15K.5 FC Product Manual, Rev. F Technical Support Seagate Technology support servicesInternet Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi Page See also cooling