Seagate ST373453LC manual Fan

Page 86

D

DAR 42

data block size modifing the 9

data heads read/write 11

data rate internal 11

data transfer rate 12 data valid eye 73

Date code page command 54 DC power 65

requirements 23

defect and error management 39 defects 39

Deferred Auto-Reallocation 42 deferred error handling 63 description 7 DEV_CTRL_CODE 71

Device Behavior page command 54 device control code values 71 Device Identification page command 54 device selection IDs 43

devices 43 dimensions 37

Disable page out command 55 disc rotation speed 11

Disconnect/reconnect control (page 02h) command 54

Download microcode and save modes (5) 56 Download microcode mode (4) 56

Download microcode with offsets and save mode (7) 56

Download microcode with offsets mode (6) 56 drive 35

drive capacity programmable 9

drive characteristics 11 drive ID 43

drive ID/option select headers 43 drive mounting 37, 44

drive orientation 43 drive select 65 driver signals 72 drivers and receivers 8 dual port support 53

E

electrical

description of connector 65 signal characteristics 71 specifications 23

electromagnetic compatibility 3 electromagnetic susceptibility 36

EMI requirements 3 enable bypass

port A 68 port B 68 signal 68

state 16

 

 

 

Enclosure Services interface

65

 

Enclosure services page command

55

environmental

 

 

 

limits 31

 

 

 

requirements 15

 

 

 

environmental control 35

 

 

 

error

 

 

 

detection mechanisms, FC 16

 

management 39

 

 

 

rates 15

 

 

 

error correction code

 

 

 

96-bit Reed-Solomon

8

 

 

Error recovery page (01h) command

54

errors 39

 

 

 

extended link service

 

 

 

frames 47

 

 

 

reply frames 47

 

 

 

Extended sense command

54

 

Extent reservation command

57

 

F

fabric

52

 

 

 

 

 

 

Fabric Address Notification (FAN)

47

Fabric Login (FLOGI)

47

 

 

FAN

52

 

 

 

 

 

 

fault LED out signal

67

 

 

FC differential input

72

 

 

FC-AL

 

 

 

 

 

 

document

5

 

 

 

 

 

interface

43,

65

 

 

 

options supported

53

 

 

physical interface

64

 

 

SCA device connector, illustrated 65

selective reset

63

 

 

 

FCC rules and regulations

3

 

FCP

 

 

 

 

 

 

 

for SCSI, document

5

 

 

response codes

48

 

 

task management functions

48

FC-PH document

5

 

 

 

 

features 8

 

 

 

 

 

 

interface

47

 

 

 

 

 

Fibre Channel documents

5

 

Fibre Channel Interface Control page (19h) 55 Fibre Channel Interface Manual 1, 3

Fibre Channel Services 47 Field pointer bytes command 54 firmware 8

corruption 57

80

Cheetah 15K.5 FC Product Manual, Rev. F

Image 86
Contents Cheetah 15K.5 FC ST3300655FC ST3146855FC ST373455FCPage Contents Interface requirements Defect and error managementInstallation Seagate Technology support services Cheetah 15K.5 FC Product Manual, Rev. F List of Figures Page Scope Cheetah 15K.5 FC Product Manual, Rev. F Electromagnetic compatibility Applicable standards and reference documentationStandards Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-20Cheetah 15K.5 FC Product Manual, Rev. F General description Standard features Media descriptionFormatted capacities PerformanceReliability Programmable drive capacityUser-installed accessories Factory-installed accessoriesFactory-installed options Seek performance characteristics Performance characteristicsInternal drive characteristics Access timeStart/stop time Format command execution time minutesGeneral performance characteristics Prefetch/multi-segmented cache controlCache operation Caching write dataPrefetch operation Recoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T MillisecondsPredictive failures Reporting controlDetermining rate Thermal monitorDrive Self Test DST State of the drive prior to testingParameter Code Description DST failure definitionShort test Function Code 001b Invoking DSTShort and extended tests Extended test Function Code 010bShipping Product warrantyAbort Product repair and return informationCheetah 15K.5 FC Product Manual, Rev. F DC power requirements Physical/electrical specificationsAC power requirements DC power requirements for ST3300655FC model Gbit AmpsDC power requirements for ST3146855FC model Gbit Amps DC power requirements for ST373455FC model Gbit AmpsConducted noise immunity General DC power requirement notesPower sequencing Current profilesTypical ST3300655FC drive, 4 Gbit, +12V current profile Typical ST3146855FC drive, 4 Gbit, +12V current profile Typical ST373455FC drive, 4 Gbit, +12V current profile Power dissipation ST3300655FCST3146855FC CURRENT/POWER vs Throughput FC 4GB ST3146855FCEnvironmental limits TemperatureST373455FC CURRENT/POWER vs Throughput FC 4GB ST373455FCShock and vibration Relative humidityEffective altitude sea level ShockPackage size Packaged/product weight Drop height Recommended mounting Acoustics Air cleanlinessVibration Corrosive environmentRoHS compliance statement Mechanical specifications Mounting configuration dimensionsCheetah 15K.5 FC Product Manual, Rev. F Drive error recovery procedures Defect and error managementDrive internal defects/errors Page FC-AL system errors Background Media ScanIdle Read After Write Media Pre-ScanDeferred Auto-Reallocation Drive orientation InstallationDrive ID/option selection CoolingDrive mounting Air flowGrounding Cheetah 15K.5 FC Product Manual, Rev. F Link services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commands Command code Command nameVerify error recovery page 07h Cheetah 15K.5 FC Product Manual, Rev. F Temperature page 0Dh Cheetah 15K.5 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mmode Sense 10 Byte Header Data Mode Sense 10 Byte Header Data 00 ae 00 10 00 00 00 08 08 8b b9 98 00 00 02 Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Power Fault LED OutMotor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Cheetah 15K.5 FC Product Manual, Rev. F Presales Support Seagate Technology support servicesInternet Technical SupportData Recovery Services Call Center Toll-free Direct dial Warranty ServiceData Recovery Services Authorized Service Centers Index NumericsFAN Flogi Plogi Page See also cooling