Seagate ST373453LC manual Parameter Code Description, Drive Self Test DST, DST failure definition

Page 27

be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.

Table 1: Temperature Log Page (0Dh)

Parameter Code

Description

 

 

0000h

Primary Temperature

 

 

0001h

Reference Temperature

 

 

5.2.6Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.

There are two test coverage options implemented in DST:

1.Extended test

2.Short text

The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.

If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.

5.2.6.1DST failure definition

The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.

The following conditions are considered DST failure conditions:

Seek error after retries are exhausted

Track-follow error after retries are exhausted

Read error after retries are exhausted

Write error after retries are exhausted

Recovered errors will not be reported as diagnostic failures.

5.2.6.2Implementation

This section provides all of the information necessary to implement the DST function on this drive.

5.2.6.2.1State of the drive prior to testing

The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.

While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.

A Drive Not Ready condition is reported by the drive under the following conditions:

Cheetah 15K.5 FC Product Manual, Rev. F

19

Image 27
Contents ST3300655FC ST3146855FC ST373455FC Cheetah 15K.5 FCPage Contents Defect and error management InstallationInterface requirements Seagate Technology support services Cheetah 15K.5 FC Product Manual, Rev. F List of Figures Page Scope Cheetah 15K.5 FC Product Manual, Rev. F Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS Ncits TR-20 Reference documentsCheetah 15K.5 FC Product Manual, Rev. F General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesFactory-installed accessories Factory-installed optionsUser-installed accessories Access time Performance characteristicsInternal drive characteristics Seek performance characteristicsPrefetch/multi-segmented cache control Format command execution time minutesGeneral performance characteristics Start/stop timeCaching write data Cache operationPrefetch operation Unrecoverable Errors Reliability specificationsError rates Recoverable ErrorsPreventive maintenance Reliability and serviceSeek errors Interface errorsMilliseconds 4 S.M.A.R.TControlling S.M.A.R.T Performance impactThermal monitor Reporting controlDetermining rate Predictive failuresDST failure definition State of the drive prior to testingParameter Code Description Drive Self Test DSTExtended test Function Code 010b Invoking DSTShort and extended tests Short test Function Code 001bProduct repair and return information Product warrantyAbort ShippingCheetah 15K.5 FC Product Manual, Rev. F DC power requirements for ST3300655FC model Gbit Amps Physical/electrical specificationsAC power requirements DC power requirementsDC power requirements for ST373455FC model Gbit Amps DC power requirements for ST3146855FC model Gbit AmpsCurrent profiles General DC power requirement notesPower sequencing Conducted noise immunityTypical ST3300655FC drive, 4 Gbit, +12V current profile Typical ST3146855FC drive, 4 Gbit, +12V current profile Typical ST373455FC drive, 4 Gbit, +12V current profile ST3300655FC Power dissipationST3146855FC ST3146855FC CURRENT/POWER vs Throughput FC 4GBST373455FC TemperatureST373455FC CURRENT/POWER vs Throughput FC 4GB Environmental limitsShock Relative humidityEffective altitude sea level Shock and vibrationPackage size Packaged/product weight Drop height Recommended mounting Corrosive environment Air cleanlinessVibration AcousticsRoHS compliance statement Mounting configuration dimensions Mechanical specificationsCheetah 15K.5 FC Product Manual, Rev. F Defect and error management Drive internal defects/errorsDrive error recovery procedures Page Background Media Scan FC-AL system errorsMedia Pre-Scan Deferred Auto-ReallocationIdle Read After Write Cooling InstallationDrive ID/option selection Drive orientationAir flow Drive mountingGrounding Cheetah 15K.5 FC Product Manual, Rev. F Interface requirements FC-AL featuresFibre Channel link service frames Link services supported Type of frameFibre Channel task management functions Fibre Channel task management responsesFC Scsi FCP response codes Function name Response code NPort login Plogi payload Bytes Fibre Channel port loginProcess Login Plri payload Fibre Channel port login acceptFibre Channel Process Login NPort Login Accept ACC payload BytesFabric Login Flogi payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Process Login Accept ACC payload BytesFabric Login Accept ACC payload Bytes Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedSupported commands Command code Command name Scsi commands supportedVerify error recovery page 07h Cheetah 15K.5 FC Product Manual, Rev. F Temperature page 0Dh Mode Sense data Inquiry dataCheetah 15K.5 FC inquiry data Bytes Data hex Page Mmode Sense 10 Byte Header Data Mode Sense 10 Byte Header Data 00 ae 00 10 00 00 00 08 08 8b b9 98 00 00 02 Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Electrical descriptionPin descriptions FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal typeFC-AL transmitters and receivers Fault LED Out PowerEnable port bypass signals Active LED OutMotor start controls 11 SEL6 through SEL0 ID lines Parallel Enclosure Services Interface ESISetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics TTL input characteristicsDevice control codes LED driver signals FC Differential outputFC Differential input Receive eye diagram Eye diagram data values Link rate GHz Cheetah 15K.5 FC Product Manual, Rev. F Technical Support Seagate Technology support servicesInternet Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services Call Center Toll-free Direct dial Numerics IndexFAN Flogi Plogi Page See also cooling