IF YOUR CO ALARM SOUNDS

SYMPTOMS OF CO POISONING

HOW CAN I PROTECT MY FAMILY?

HOW YOUR CO ALARM WORKS, Continued

INSTALLATION, continued

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. When your CO Alarm sounds, you must not ignore it!

IF THE ALARM SOUNDS:

1.

Operate the Test/Silence button to silence the alarm.

2.

Call your emergency services, fire department or 911. Write down the

 

number of your local emergency service here:

 

________________________________________________________________

3.

Immediately move to fresh air—outdoors or by an open door or window.

 

Do a head count to check that all persons are accounted for. Do not re-

 

enter the premises, or move away from the open door or window until the

 

emergency services responder has arrived, the premises have been aired

These symptoms are related to CO POISONING and should be discussed with ALL household members.

Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).

Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate.

Extreme Exposure: Convulsions, unconsciousness, heart and lung failure. Exposure to Carbon Monoxide can cause brain damage, death.

This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults.

Why is this important? Because you need to be warned of a potential CO

A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults.

A CO Alarm is not a substitute for proper maintenance of home appliances.

To help prevent CO problems and reduce the risk of CO poisoning:

• Clean chimneys and flues yearly. Keep them free of debris, leaves, and

nests for proper air flow. Also, have a professional check for rust and

corrosion, cracks, or separations. These conditions can prevent proper

air movement and cause backdrafting. Never “cap” or cover a chimney

in any way that would block air flow.

• Test and maintain all fuel-burning equipment annually. Many local gas or

oil companies and HVAC companies offer appliance inspections for a

nominal fee.

USER’S MANUAL

AC POWERED

CARBON MONOXIDE ALARM

120VAC ~, 60Hz, 0.09A

DISPLAY CONDITIONS (CO5120PDBN)

Alarm operating

Alarm operating

Low / missing

“Err” Alarm is

on AC power

on emergency

battery warning

not operating

 

battery back-up

 

properly

What you see and hear if CO is detected:

BEFORE YOU BEGIN INSTALLATION

This unit is designed to be mounted on any standard wiring junction box up to a 4-inch (10 cm) size, on either the ceiling or wall. Read “Where to Install CO Alarms” and “Where Not To Install CO Alarms” before you begin installation.

If a junction box is not already in place, install one using standard #12 or #14 gauge copper wire.

• This Alarm must have AC or battery power to operate. If the AC

power fails, the battery back-up will power the Alarm for a short

time if the 9V battery is fresh and correctly installed. If AC power

fails, and the battery is dead or missing, the Alarm cannot operate.

• Make sure the alarm is not receiving excessive noisy power.

STAND ALONE ALARM ONLY:

If you are only installing one unit, restore power to the junction box.

INTERCONNECTED ALARMS ONLY:

If you are interconnecting multiple Alarms, repeat Step 1-5 for each Alarm in the series. When you are finished, restore power to the junction box.

ELECTRICAL SHOCK HAZARD. Do not restore power until all Alarms are completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death.

out, and your CO Alarm remains in its normal condition.

4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour period,

repeat steps 1-3 and call a qualified appliance technician to investigate for

sources of CO from fuel-burning equipment and appliances, and inspect for

proper operation of this equipment. If problems are identified during this

inspection have the equipment serviced immediately. Note any combustion

equipment not inspected by the technician, and consult the manufacturers’

instructions, or contact the manufacturers directly, for more information about

CO safety and this equipment. Make sure that motor vehicles are not, and

have not, been operating in an attached garage or adjacent to the residence.

Write down the number of a qualified appliance technician here:

_________________________________________________________________

Alarms have various limitations. See "General Limitations of CO Alarms" for details.

problem while you can still react in time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disoriented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!

FINDING THE SOURCE OF CO AFTER AN ALARM

Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:

• House well ventilated before the investigator arrives.

• Make regular visual inspections of all fuel-burning appliances. Check

appliances for excessive rust and scaling. Also check the flame on the

burner and pilot lights. The flame should be blue. A yellow flame means

fuel is not being burned completely and CO may be present. Keep the

blower door on the furnace closed. Use vents or fans when they are

available on all fuel-burning appliances. Make sure appliances are vented

to the outside. Do not use grills or barbecue indoors, or in garages or on

screen porches.

• Check for exhaust backflow from CO sources. Check the draft hood on

an operating furnace for a backdraft. Look for cracks on furnace heat

exchangers.

• Check the house or garage on the other side of shared wall.

• Keep windows and doors open slightly. If you suspect that CO is escaping

into your home, open a window or a door. Opening windows and doors

can significantly decrease CO levels.

 

WITH BATTERY BACK-UP

 

WITH BATTERY BACK-UP

 

Model CO5120BN

 

AND DIGITAL DISPLAY

 

 

 

Model CO5120PDBN

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT! PLEASE READ CAREFULLY AND SAVE.

 

 

This user’s manual contains important information

 

 

about your CO Alarm’s operation. If you are installing

 

 

this CO Alarm for use by others, you must leave this

 

 

manual—or a copy of it—with the end user.

Models

 

 

 

 

 

 

 

 

CO5120BN,

PRE-ALARM LEVELS :

HORN: Silent

DISPLAY: Shows CO levels detected in ppm (CO5120PDBN)

POWER/ALARM LIGHT:

On continuously

ALARM LEVELS OF CO ARE DETECTED:

HORN: Sounds loudly - 4 beeps, pause, 4 beeps, pause.

This sequence repeats for as long as the unit is in alarm*

DISPLAY: Shows CO levels

IF YOU SILENCE THE ALARM:

HORN: Silent for about 4 minutes*

DISPLAY: Shows CO levels detected in ppm (CO5120PDBN)

POWER/ALARM LIGHT:

Flashes rapidly

*Note: After 4 minutes, if CO levels drop below alarm levels, the unit will remain silent and return to normal operation. If CO present still indicates a potentially dangerous situation, the horn will sound again.

Examples of noisy power could be major appliances on the same

circuit, power from a generator or solar power, light dimmer on the

same circuit or mounted near fluorescent lighting. Excessive noisy

power may cause damage to your Alarm.

Find the pair of self-adhesive labels included with this CO Alarm.

On each label write in the phone number of your emergency responder (like 911) and a qualified appliance technician.

Place one label near the CO Alarm, and the other label in the “fresh air” location you plan to go if the alarm sounds.

NOTE: A qualified appliance technician is defined as “a person, firm, corporation, or company that either in person or through a representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appliances and equipment, and/or gas fireplaces or other decorative combustion equipment.”

6.

Make sure the CO Alarm is receiving AC power. Under normal operation,

 

the red indicator light will shine continuously. If the red power indicator light

 

does not light, TURN OFF POWER TO THE JUNCTION BOX and recheck

 

all connections. If all connections are correct and the red power indicator

 

still does not light when you restore the power, the unit should be replaced

 

immediately.

7.

ACTIVATING THE BATTERY BACK-UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activate the battery back-up by removing the “Pull to Activate Battery

 

Back-Up” tab. You do not need to open the battery compartment and

 

reposition the battery during installation. DO NOT remove the battery

 

activation tab until AC power is turned on to conserve battery power.

8.

Test the CO Alarm. Press and hold the test button on the cover until the

 

alarm sounds: 4 beeps, pause, 4 beeps, pause. In a series of interconnected

 

Alarms, you must test each Alarm separately by pressing and holding the

USING THE SILENCE FEATURE

NEVER disconnect the power to your CO Alarm to silence the horn— use the silence feature. Disconnecting the CO Alarm removes your protection! See previous page for details on responding to an alarm.

The Silence Feature is intended to temporarily silence your CO Alarm’s alarm horn while you correct the problem—it will not correct a CO problem. While the Alarm is silenced, it will continue to monitor the air for CO. When CO reaches alarm level, the unit will sound— repeating horn pattern: 4 beeps, a pause, 4

• Problem caused by “backdrafting.”

• Transient CO problem caused by special circumstances.

Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.

POTENTIAL SOURCES OF CO IN THE HOME

Fuel-burning appliances like:

portable heater, gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer.

UNDERWRITERS LABORATORIES INC. UL2034

WHAT LEVELS OF CO CAUSE AN ALARM?

Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over time (in minutes).

UL2034 Required Alarm Points*:

• If the Alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN

4 and 15 MINUTES

M08-0002-002 Q 04/07 Printed in Mexico

CO5120PDBN

 

INTRODUCTION

Thank you for choosing BRK Brands, Inc. for your Carbon Monoxide Alarm needs. You have purchased a state-of-the-art Carbon Monoxide Alarm designed to provide you with early warning of carbon monoxide.

Key features include:

Intelligent Sensing Technology is designed to help reduce unwanted or nuisance alarms.

detected in ppm (CO5120PDBN)

POWER/ALARM LIGHT:

Flashes rapidly

*Note: If unit goes into alarm under battery back-up power, the regular 4 beeps-brief pause cycle will repeat for four minutes. After four minutes, the pause will increase to 1 minute.

IF THE CO LEVELS RETURN TO NORMAL:

HORN: Silent

DISPLAY: Dash lit by “READY” (CO5120PDBN)

POWER/ALARM LIGHT:

Shines continuously

1

2

3

4

7

3

2

6

5

PARTS OF THIS CO ALARM

1

Mounting Bracket

2

Mounting Slot and Screw*

 

 

3

Locking Pins (break out of

 

bracket)

 

 

4

Hot (Black) AC Wire

 

 

5

Neutral (White) AC Wire

 

 

6

Interconnect Wire (Orange)

 

 

7

Lever to Open Battery

test button. Make sure all units alarm when each one is tested.

If any unit in the series does not alarm during testing, TURN OFF POWER and recheck connections. If it does not alarm when you restore power, replace it immediately.

SPECIAL REQUIREMENTS FOR INTERCONNECTED CO ALARMS

• Failure to meet any of the above requirements could damage the

units and cause them to malfunction, removing your protection.

beeps, etc. Press and hold the Test/Silence button until the horn is silent. The Silence cycle will last approximately 4 minutes.

To silence an interconnected series of Alarms, you must press the Test/ Silence button on the initiating alarm (the unit with the flashing red light).

If you press the Test/Silence on any other Alarm, it will only silence that unit, not the whole interconnected series.

NOTE: After the 4-minute silence cycle, the CO Alarm re-evaluates present CO levels and responds accordingly. If CO levels remain potentially dangerous—or start rising higher—the horn will start sounding again.

Damaged or insufficient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening.

Improper use of appliance/ device: operating a barbecue grill or vehicle in an enclosed area (like

• If the Alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN

10 and 50 MINUTES.

• If the Alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN

60 and 240 MINUTES.

* Approximately 10% COHb exposure at levels of 10% to 95% Relative

Humidity (RH).

The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

Single Button Test/Silence eliminates confusion. Depending on what mode the alarm is in, pushing the button provides different functions such as testing the alarm, silencing the alarm or low-battery signal, re-testing the alarm when in silence and clearing the Latching feature.

Latching Alarm Indicator easily identifies initiating alarm even after the alarm condition has subsided.

Smart Interconnect interconnects with most First Alert® and BRK branded smoke, CO and heat alarms. When interconnected with alarming smoke

SMART INTERCONNECT FEATURE

This CO Alarm includes “Smart Interconnect” which enables the Alarm to be interconnected with other BRK Smoke and CO Alarms. When interconnected to Smoke Alarms that go into alarm, this CO Alarm will sound the smoke horn pattern.

USING THE PEAK CO MEMORY (CO5120PDBN)

The CO Memory Feature lets you check the highest level of CO recorded

8

9

 

Compartment

8

Swing-Out Battery

 

Compartment

 

 

9

Quick-Connect Power

 

 

 

*Not Included

• AC and AC/DC CO Alarms can be interconnected. Under AC power,

all units will alarm when one senses CO. When power is interrupted,

only the AC/DC units in the series will continue to send and receive

signals. AC powered CO Alarms will not operate.

Interconnected units can provide earlier warning of a CO problem than stand- alone units, especially if the problem starts in a remote area of the dwelling. If any unit in the series senses CO, all units will alarm. To determine which CO Alarm initiated an alarm, refer to the table.

While the CO Alarm is silenced:

If the CO Alarm...is silent for only 4 minutes, then starts sounding loudly—4 beeps, then a pause, 4 beeps, then a pause. Red light (LED) continues flashing...

This means...CO levels are still potentially dangerous.

If the CO Alarm...remains silent....

This means...unit has returned to normal operation.

SILENCING THE LOW BATTERY WARNING

This silence feature can temporarily quiet the low battery warning “chirp” for up to 8 hours if AC power is present. Press the Test/Silence button on the alarm cover. Once the low battery warning “chirp” silence feature is activated, the unit continues to flash the red light once a minute for 8 hours. After 8 hours, the low battery “chirp” will resume. Replace the battery as soon as possible, to maintain protection in the event of a power outage.

THE “LATCHING ALARM” INDICATOR:

 

 

 

KEY:

 

 

 

LATCHING ALARM:

 

 

 

Unit was exposed

BEDROOM

BEDROOM

BEDROOM

to alarm levels of CO

a garage or screened porch).

Transient CO Problems: “transient” or on-again-off-again CO problems can be caused by outdoor conditions and other special circumstances.

The following conditions can result in transient CO situations:

1.Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:

Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with extended periods between cycles).

Negative pressure differential resulting from the use of exhaust fans.

Several appliances running at the same time competing for limited fresh air.

Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.

Obstructions in or unconventional vent pipe designs which can amplify the above situations.

2.Extended operation of unvented fuel burning devices (range, oven, fireplace).

3.Temperature inversions, which can trap exhaust close to the ground.

4.Car idling in an open or closed attached garage, or near a home.

These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.

CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present.

An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.

An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.

Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034.

According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and is designed to alarm before CO levels become life threatening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.

Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.

Audible Alarm: 85 dB minimum at 10 feet (3 meters).

alarms, unit will sound smoke horn pattern.

Dust Cover is included to keep the alarm clean during construction.

Easy Installation/Maintenance features include a large opening in the mounting bracket for easy access to wiring. A battery pull tab keeps the battery fresh until the home is occupied. A Side Load Battery Drawer allows for easy battery replacement without removing the alarm from the ceiling or wall.

© 2007 BRK Brands, Inc., a subsidiary of Jarden Corporation. 3901 Liberty Street Road, Aurora, IL 60504-8122

All rights reserved.

Consumer Affairs: (800) 323-9005 www.brkelectronics.com • www.firstalert.com

BASIC SAFETY INFORMATION

• Dangers, Warnings, and Cautions alert you to important

operating instructions or to potentially hazardous situations.

Pay special attention to these items.

• THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to

detect carbon monoxide from ANY source of combustion. It is

NOT designed to detect smoke, fire, or any other gas.

• This CO Alarm is approved for use in single-family residences. It is

NOT designed for marine or RV use.

• This CO Alarm will only indicate the presence of carbon monoxide

gas at the sensor. Carbon monoxide gas may be present in other

during an alarm.

To check CO Memory:

1.Press and release the Test/Silence/Scroll button until the dash scrolls to “MEMORY”.

2.Press and hold Test/Silence/Scroll button to display Memory CO level.

To clear CO Memory:

1.Press and release the Test/Silence/Scroll button until the dash scrolls to “CLEAR MEMORY.”

2.Press and hold the Test/Silence/Scroll button until the display shows “CLr.”

NOTE: The highest CO level will be saved, even after a power interruption, until you clear it. DO NOT clear the CO Memory reading if you plan to call someone to investigate a CO problem! Clear the CO Memory reading only after the investigator has checked your home.

INSTALLATION

WHERE TO INSTALL CO ALARMS

The National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every level of your home.

If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm at BOTH ends of the hallway.

HOW TO INSTALL YOUR CO ALARM

Tools you will need: Standard Flathead screwdriver.

ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death.

To install this unit:

1.Remove the mounting bracket from the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws.

2.Using wire nuts, connect the power connector to the AC power.

Improper wiring of the power connector or the wiring leading to the power connector will cause damage to the Alarm and may lead to a non-functioning Alarm.

STAND ALONE ALARM ONLY:

Connect the white wire on the power connector to the neutral wire in the junction box.

Connect the black wire on the power connector to the hot wire in the junction box.

Tuck the orange wire inside the junction box. It is used for interconnect only.

INTERCONNECTED ALARMS ONLY:

On Initiating CO Alarm

Red LED Flashes Once per Second

On All Other CO Alarms

Red LED Does Not Flash Once per Second

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interconnect units within a single family residence only. Otherwise all house- holds will experience unwanted alarms when you test any unit in the series. Interconnected units will only work if they are wired to compatible units and all requirements are met. This unit is designed to be compatible with: BRK Electronics® Smoke Alarm Models SC6120B, 4120, 4120B, 4120SB, 4919, 2002RAC, 100S, 5919, 5919TH; BRK Electronics® Heat Alarm Models HD6135F, HD6135FB; BRK Electronics® CO Alarm Models SC6120B, CO5120BN, CO5120PDBN; and First Alert® Smoke Alarm Models SA4120B, SA4121B, SA4919B, SA100B.

Interconnected units must meet ALL of the following requirements:

A maximum of 18 compatible BRK Electronics® Smoke, Heat or CO Alarms may be interconnected. No more than 12 of the 18 can be Smoke Alarms per NFPA 72.

The same fuse or circuit breaker must power all interconnected units.

The total length of wire interconnecting the units should be less than 1000 feet. The interconnect wire should be Type 18 gauge AWM or larger, rated at least 300V. If an interconnect wire is not already part of your household wiring, you will need to install one. This type of wire is commonly available at Hardware and Electrical Supply stores.

All wiring must conform to all local electrical codes and Article 760 of the National Electrical Code. Refer to NFPA, Chapter 2 and/or your local building code for further connection requirements.

 

LATCHING NOT ACTIVATED:

KITCHEN GARAGE

Unit was not exposed

 

to alarm levels of CO

GENERAL LIMITATIONS OF CO ALARMS

areas.

Strip off about 1/2” of the plastic coating on the orange interconnect wire on the power connector.

A}

6￿

87￿} B

LIVING ROOM

HALL

 

BASEMENT

The Latching Alarm Indicator is activated after a CO Alarm is exposed to alarm levels of carbon monoxide. After CO levels drop below alarm levels, the red LED will begin to flash once every 5 seconds. It will continue to flash or “latch” until you clear it by testing the alarm.

This feature helps emergency responders, investigators, or service technicians identify which unit(s) in your home were exposed to alarm levels of carbon monoxide. This can help investigators pinpoint the source of CO.

Interconnected Alarms. Latching Alarm Indicator shows which Alarm(s) in the series were exposed to alarm levels of carbon monoxide.

The Latching Alarm Indicator stays ON until you clear it, so it can alert you to a CO Alarm that occurred while you were away from home, even though CO present in the air has dropped below alarm levels.

This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met.

CO alarms may not waken all individuals. If children or others do not readily waken to the sound of the CO alarm, or if there are infants or family members with mobility limitations, make sure that someone is assigned to assist them in the event of an emergency.

CO Alarms will not work without power. This CO Alarm requires a continuous supply of AC power, and a fresh, correctly installed 9V battery to power the battery back-up. The battery back-up is for emergency use only!

CO Alarms for Solar or Wind Energy users and battery backup power systems: AC powered CO Alarms should only be operated with true or pure sine wave inverters. Operating this CO Alarm with most battery-powered UPS (uninterruptible power supply) products or square wave or “quasi sine wave” inverters will damage the Alarm. If you are not sure about your inverter or UPS type, please consult with the manufacturer to verify.

This CO Alarm will not sense carbon monoxide that does not reach the sensor. This CO Alarm will only sense CO at the sensor. CO may be present

CO Alarms may not be heard. The Alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This CO Alarm is not intended for people who are hearing impaired.

CO Alarms are not a substitute for a smoke alarm. Although fire is a source of carbon monoxide, this CO Alarm does not sense smoke or fire. This CO Alarm senses CO that may be escaping unnoticed from malfunctioning furnaces, appliances, or other sources. Early warning of fire requires the installation of smoke alarms.

CO Alarms are not a substitute for life insurance. Though these CO Alarms warn against increasing CO levels, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives from CO poisoning. Homeowners and renters must still insure their lives.

• This unit does not work without power. If the AC power fails, the

battery back-up will power the alarm for at least 7 days provided

the 9V battery is fresh and correctly installed.

• The Silence Feature is for your convenience only and will not correct

a CO problem. Always check your home for a potential problem after

any alarm. Failure to do so can result in injury or death.

• This CO Alarm should receive continuous 120VAC, 60 Hz, pure sine

wave electrical power. (The battery is meant for emergency back-

up only). Do not use in an extension cord or outlet controlled by a

dimmer or switch. In order for the emergency battery back-up to

work, a working (fresh) battery must be properly installed.

• NEVER ignore any alarm. See “If Your CO Alarm Sounds” for more

information on how to respond to an alarm. Failure to respond can

result in injury or death.

• Test this Carbon Monoxide Alarm once a week. If it ever fails to

test correctly, have it replaced immediately! If the CO Alarm is not

BEDROOM

BEDROOM

BEDROOM

 

KITCHEN

GARAGE

LIVING ROOM

HALL

 

 

BASEMENT

 

REQUIRED TO MEET NFPA RECOMMENDATIONS

SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS

In a Single-level Home:

• Install at least one CO Alarm near or within each separate sleeping area.

Connect the white wire on the power connector to the neutral wire (usually white) in the junction box.

Connect the black wire on the power connector to the hot wire (usually black) in the junction box.

Connect the orange wire on the power connector to the interconnect wire in the junction box. Repeat for each unit you are interconnecting. Never connect the hot or neutral wires in the junction box to the orange interconnect wire.

3.Plug the power connector into the back of the CO Alarm.

4.Position the base of the Alarm over the mounting bracket and turn. The Alarm can be positioned over the bracket every 60°. Turn the unit clockwise (right) until the unit is in place.

5.Check all connections.

5

5

4

4

3

3

2

 

1

1

 

A. Unswitched 120VAC

B. To Additional Alarms,

 

 

60 Hz source

 

 

Maximum = 18 Alarms

 

 

 

 

 

 

 

 

 

 

 

 

 

1. CO Alarm

4. Wire Nut

 

 

7. Interconnect Wire

2. Ceiling or Wall

5. Junction Box

 

(Orange)

 

8. Hot Wire (Black)

3. Power Connector

6. Neutral Wire (White)

 

 

 

 

 

 

 

 

 

WEEKLY TESTING

Push and hold the Test/Silence button until you hear an acknowledge chirp and a loud alarm sounds — 4 beeps, pause, 4 beeps. This sequence should last for 10 seconds. If the Alarm ever fails to test properly, replace it immediately. If the Alarm is not working properly, refer to “Limited Warranty”.

in other areas. Doors or other obstructions may affect the rate at which CO reaches the CO Alarm. For this reason, if bedroom doors are usually closed at night, we recommend you install a CO Alarm in each bedroom and in the hallway between them.

CO Alarms may not sense CO on another level of the home. For example, a CO Alarm on the second level, near the bedrooms, may not sense CO in the basement. For this reason, one CO Alarm may not give adequate warning.

Complete coverage is recommended. Place CO Alarms on each level of the home.

CO Alarms have a limited life. Although the CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test your CO Alarm weekly.

CO Alarms are not foolproof. Like all other electronic devices, CO Alarms have limitations. They can only detect CO that reaches their sensors. They may not give early warning to rising CO levels if the CO is coming from a remote part of the home, away from the CO Alarm.

working properly, it cannot alert you to a problem.

• This product is intended for use in ordinary indoor locations of

family living units. It is not designed to measure CO levels in

compliance with Occupational Safety and Health Administration

(OSHA) commercial or industrial standards. Individuals with

medical conditions that may make them more sensitive to carbon

monoxide may consider using warning devices which provide

audible and visual signals for carbon monoxide concentrations

under 30 ppm. For additional information on carbon monoxide and

• For added protection, install an additional CO Alarm at least 20 feet

(6 meters), away from the furnace or fuel burning heat source.

In a Multi-level Home—(same as above plus):

• Install at least one CO Alarm near or within each separate sleeping area.

• For added protection, install at least one CO Alarm on each level of the

home. If you have a basement, install that CO Alarm at the top of the

basement stairs.

• For added protection, install an additional CO Alarm at least 20 feet

USING THE OPTIONAL LOCKING FEATURES

The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or alarm removal is not a concern.

These CO Alarms have two separate locking features: one locks the battery

 

compartment, and the other locks the CO Alarm to the mounting bracket.

Locking Pin

• If the Alarm ever fails to test properly, replace it immediately.

Products under warranty may be returned to the manufacturer for

replacement. See “Limited Warranty” at the end of this manual.

• DO NOT stand close to the Alarm when the horn is sounding.

Exposure at close range may be harmful to your hearing. When

testing, step away when horn starts sounding.

TROUBLESHOOTING GUIDE

 

 

 

The following guide can help you identify a potential problem with the

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where

installation or operation of your CO Alarm. NOTE: It is not meant to be

your medical condition contact your physician.

HOW YOUR CO ALARM WORKS

The Cover Of Your CO Alarm

51. Test/Silence Button

(6 meters) away from the furnace or fuel burning heat source.

WHERE CO ALARMS SHOULD NOT BE INSTALLED

DO NOT locate this CO Alarm:

You can choose to use either feature independently, or use them both.

Tools you will need: Needle-nose pliers • Standard Flathead screwdriver.

Both locking features use locking pins, molded into the mounting bracket. Using needle nose pliers remove one or both pins, depending on which locking features you use.

• NEVER use vehicle exhaust! Exhaust may cause permanent damage

and voids your warranty.

REGULAR MAINTENANCE

To keep the CO Alarm working properly:

Test it every week as described in “Weekly Testing.”

Vacuum the CO Alarm cover at least once a month, using the soft brush attachment. Never use water, cleaners, or solvents, since they may damage the unit. Test the Alarm again after vacuuming.

Replace the battery immediately when you see/hear the “Low Battery Warning”.

The Low (or Missing) Battery Warning (CO5120PDBN):

The horn will “chirp” once a minute and the word “bat” will flash on and off on the display.

REPLACING THE BATTERY

Choosing a replacement battery: This unit requires one standard 9V alkaline battery. The following alkaline batteries are acceptable as replacements: Duracell #MN1604 or MX1604; Eveready “Energizer” 522. You can also use an Ultralife 9 volt lithium battery #U9VL for longer service life between battery changes. These replacement batteries are commonly available at local retail stores.

Use only the alkaline or lithium replacement batteries listed. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause permanent damage.

Household cleaners, aerosol chemicals and other contaminants can affect the sensor. When using any of these materials near the CO Alarm, make sure the room is well ventilated.

If your home is being fumigated, unplug the unit temporarily and put it where it will not be exposed to chemicals or fumes. When fumigation is complete and all traces of fumes clear, plug the unit back in and retest it.

WHAT YOU NEED TO KNOW ABOUT CO

WHAT IS CO?

CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO.

These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.

Common appliances are often sources of CO. If they are not properly main- tained, are improperly ventilated, or malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. “Air-tight” homes with added insulation, sealed windows, and other weatherproofing can “trap” CO inside.

 

the CO Alarm is installed BEFORE removing it from the mounting

an all-inclusive list of all CO Alarm conditions. If you are experiencing a

 

bracket or checking any electrical connections! Failure to turn off the

condition not covered in the next several pages, please contact Consumer

 

power first may result in serious electrical shock, injury or death.

Affairs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem...

If the Alarm..

 

You should...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red light is OFF. Unit will not alarm when you press

Unit may not be receiving any power.

Check the AC power supply. Make sure the power

 

the Test/Silence button.

 

 

connector is securely attached to the Alarm. Make

 

 

 

 

 

 

 

sure a fresh 9V battery is installed to power the

 

 

 

 

 

 

 

battery back-up.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red light flashes once a minute (horn is silent).

Alarm is not receiving AC power.

Unit is operating on DC battery back-up. Check the

 

(CO5120PDBN display reads “bat”).

 

 

AC power supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Once a minute, the red light flashes and the horn

Low battery warning.

 

Replace the 9V battery in the battery back-up.

 

“chirps”. (CO5120PDBN display flashes “bat”).

 

 

Disconnect AC power before changing the battery.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Once a minute, the alarm sounds 3 quick “chirps”,

MALFUNCTION SIGNAL. Based on its Self Test

Make sure a fresh 9V battery is installed. If unit still

 

and the red light flashes quickly three times.

diagnostics, the unit has detected a malfunction.

isn’t functioning– REPLACE IT. Units under warranty

 

 

(CO5120PDBN display reads “Err”).

The unit needs to be replaced.

 

should be returned to manufacturer for

 

 

 

 

 

replacement. See “Limited Warranty” for details.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO Alarm goes back into alarm 4 minutes after

CO levels are still potentially dangerous.

Refer to “If Your CO Alarm Sounds” for details on

 

you press the Test/Silence button.

 

 

how to respond to an alarm. If anyone is feeling ill,

 

 

 

 

 

EVACUATE your home immediately and call 911.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO Alarm sounds frequently even though no high

The CO Alarm may be improperly located.

Relocate your Alarm. If frequent alarms continue, have

 

levels of CO are revealed in an investigation.

Refer to “Where to Install CO Alarms.”

home rechecked for potential CO problems. You may

 

 

 

 

 

be experiencing an intermittent CO problem.

 

 

 

 

 

 

 

 

 

 

 

LIMITED WARRANTY

BRK Brands, Inc., ("BRK") the maker of First Alert® brand products warrants that for a period of five years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and conditions of this warranty.

This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.

BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.

How to Obtain Warranty Service

Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when calling. For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906

Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect to battery.

For your records, please record:

Replacement date is five years after installation:

Date Purchased: _______________Where Purchased: __________________

_____________/____________Month/Year

NOTE: End of Life Signal — Once the unit reaches the end of its lifecycle,

 

 

the MALFUNCTION SIGNAL will sound once a minute to indicate the need

Date Installed: ____________/____________Month/Year

to immediately replace the Alarm.

 

 

First Alert® is a registered trademark of the First Alert Trust.

Printed in Mexico M08-0002-002 Q 04/07

2

Scroll Button (CO5120PDBN)

 

32. POWER/ALARM Light (RED)

1

4

3. Air Vents

4. (Behind the Cover) Alarm Horn:

85 dB audible alarm for test, alarm, and unit malfunction warning.

5. Digital Display (CO5120PDBN)

UNDERSTANDING THE LIGHT AND HORN PATTERNS (CO5120BN)

Condition

LED (Red Light)

Horn

POWER UP

LED flashes on once,

Horn “chirps”

 

then shines continuously

once.

DURING TESTING

LED flashes once every second

Horn pattern:

 

during the test cycle

4 beeps, pause,

 

 

4 beeps, pause

LOW OR MISSING

LED flashes once a minute

Horn “chirps”

BATTERY

 

once a minute

MISSING OR DEAD

LED is OFF

Horn is silent

BATTERY (DC back-

 

 

up disabled

 

 

WARNING: When the AC power is Off, if the battery is dead or missing, the CO Alarm cannot work.

ALARM CONDITION

LED flashes once every second

Horn pattern:

Single CO Alarm

 

4 beeps, pause,

(not interconnected)

 

4 beeps, pause,

 

 

repeating

 

 

 

ALARM CONDITION

LED flashes rapidly on the units

Horn pattern:

Interconnected

that triggered the alarm. LEDs

4 beeps, pause,

Series of CO Alarms

on the other Alarms in the series

repeating on all

 

will not flash

CO Alarms

IN SILENCE MODE

LED flashes once every second

Horn stays quiet

 

on initiating Alarm

for 4 minutes

“LATCHING” ALARM

LED Flashes once every

Horn stays quiet

INDICATOR

5 seconds

 

MALFUNCTION

LED flashes 3 times

Horn sounds

 

synchronized with 3 rapid chirps

3 rapid chirps

 

 

(chirp-chirp-chirp)

 

 

every minute

• In garages, kitchens, furnace rooms, or in any extremely dusty, dirty

or greasy areas.

• Where combustion particles are produced. Combustion particles form

when something burns. Areas to avoid include poorly ventilated kitchens,

garages, and furnace rooms. Keep units at least 20 feet (6 meters) from

the sources of combustion particles (stove, furnace, water heater, space

heater) if possible. In areas where a 20-foot (6 meter) distance is not

possible — in modular, mobile, or smaller homes, for example — it is

recommended the CO Alarm be placed as far from these fuel-burning

sources as possible. The placement recommendations are intended to

keep these Alarms at a reasonable distance from a fuel-burning source,

and thus reduce “unwanted” alarms. Unwanted alarms can occur if a CO

Alarm is placed directly next to a fuel-burning source. Ventilate these areas

as much as possible.

• Within 5 feet (1.5 meter) of any cooking appliance.

• In extremely humid areas. This Alarm should be at least 10 feet (3 meter)

from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry

room, utility room or other source of high humidity.

• In areas where temperature is colder than 40˚ F (4˚ C) or hotter than 100˚ F

(38˚ C). These areas include non-airconditioned crawl spaces, unfinished

attics, uninsulated or poorly insulated ceilings, porches, and garages.

• In turbulent air, like near ceiling fans, heat vents, air conditioners,

fresh air returns, or open windows. Blowing air may prevent CO from

reaching the sensors.

• In direct sunlight.

• This CO Alarm is designed for use inside a single-family home or

apartment. It is not meant to be used in common lobbies, hallways,

or basements of multi-family buildings unless working CO Alarms

are also installed in each family living unit. CO Alarms in common

areas may not be heard from inside individual family living units.

• This CO Alarm alone is not a suitable substitute for complete

detection systems in places which house many people, like hotels

or dormitories, unless a CO Alarm is also placed in each unit.

• DO NOT use this CO Alarm in warehouses, industrial or commercial

buildings, special-purpose non-residential buildings, RVs, boats,

or airplanes. This CO Alarm is specifically designed for residential

use, and may not provide adequate protection in non-residential

applications.

THE BATTERY COMPARTMENT LOCK

TO LOCK THE BATTERY COMPARTMENT:

Do not lock the battery compartment until you have activated the battery and tested the battery back-up.

1. Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. Push and hold the test button on the CO Alarm’s cover until you hear an acknowledge chirp and the alarm sounds: 4 beeps, pause, 4 beeps, pause.

If the unit does not alarm during testing, DO NOT lock the battery compartment! Install a new battery and test again. If it still does not alarm, replace the CO Alarm immediately.

2. Using needle-nose pliers, detach one locking pin from the mounting bracket.

3. Push the locking pin through the black dot on the label on the back of the CO Alarm.

TO UNLOCK THE

BATTERY COMPARTMENT:

Once the CO Alarm is installed, you must disconnect it from the AC power before unlocking the battery compartment.

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.

Always discharge the branch circuit before servicing an AC or AC/DC CO Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Alarms with battery back-up. Finally, press and hold the test button for 5-10 seconds to discharge the branch circuit.

1.Remove the CO Alarm from the mounting bracket. If the unit is locked to the bracket, see the section “To Deactivate the Locking Feature.”

2.Disconnect the power connector by gently prying it away from the back of the CO Alarm.

3. Insert a flathead screwdriver under the head of the locking pin, and gently pry it out of the battery compartment lock. (If you plan to relock the battery compartment, save the locking pin.)

4. To relock the battery compartment, close the bat- tery door and reinsert the locking pin in the lock.

5.Reconnect the power connector to the back of the CO Alarm, reattach the CO Alarm to the mounting bracket, and restore the power.

When replacing the battery, always test the CO Alarm before relocking the battery compartment.

THE MOUNTING BRACKET LOCK

Tools you will need:

Needle-nose pliers

• Standard Flathead screwdriver

TO ACTIVATE THE BRACKET LOCK:

1. Using needle-nose pliers, detach one locking pin from the mounting bracket.

2. Insert the locking pin into the lock located on the pivoting hinge of the battery door.

3. When you attach the CO Alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.

TO DEACTIVATE THE BRACKET LOCK:

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.

Always discharge the branch circuit before servicing an AC or AC/DC CO Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Alarms with battery back-up. Finally, press and hold the test button.

1. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket.

2. Pry the CO Alarm away from the bracket by turning both the screwdriver and the CO Alarm counterclockwise (left) at the same time.

TO PERMANENTLY REMOVE THE BRACKET LOCK:

Insert the flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.

5

6

7

1

2

3

4

Page 1
Image 1
BRK electronic C05120BN user manual If Your CO Alarm Sounds, USER’S Manual, Underwriters Laboratories INC. UL2034

C05120BN, CO5120PDBN specifications

The BRK electronic CO5120PDBN and C05120BN are advanced carbon monoxide (CO) alarms designed to provide reliable protection against the dangers of carbon monoxide poisoning. These models are particularly noteworthy for their advanced features, technologies, and user-friendly specifications, making them an essential addition to any home safety system.

One of the standout features of the CO5120PDBN and C05120BN is their electrochemical sensor technology. This technology is known for its high sensitivity and accuracy in detecting carbon monoxide levels in the air. Unlike other detection methods, electrochemical sensors are less prone to false alarms, ensuring that users are only alerted when CO levels reach a dangerous threshold. This is crucial for maintaining trust in the alarm system, as users can differentiate between real threats and false warnings.

The alarms also come equipped with a digital display, which provides real-time readings of CO levels in the environment. This display allows users to see not only when the alarm is triggered but also the concentration of CO detected, empowering them to take informed actions. Additionally, the integrated test and reset button makes routine checks straightforward, allowing homeowners to ensure their device is operational with a simple press.

In terms of installation, both models boast a sleek design and are easy to mount on walls or set up on flat surfaces. The battery-operated functionality eliminates the need for hard wiring, which simplifies installation and means that the detectors can be placed anywhere they are most needed – such as near sleeping areas or in hallways.

Another essential characteristic is the alarm's lifespan. The CO5120PDBN and C05120BN have a typical sensor lifespan of up to seven years, after which users will be prompted to replace the unit. This feature ensures that users are always protected, as outdated alarms can fail to operate effectively.

Moreover, the alarms feature an end-of-life signal that alerts users when it’s time to replace the device completely. This proactive approach to safety ensures that households remain vigilant against the risks associated with carbon monoxide exposure.

Additionally, these models include an optional voice alert system that provides clear spoken warnings, enhancing the effectiveness of the alarm and informing occupants of the specific danger detected. This helps individuals recognize the severity of the situation more rapidly, especially in emergencies.

In summary, the BRK electronic CO5120PDBN and C05120BN are equipped with cutting-edge technology and features that ensure effective and reliable detection of carbon monoxide. With electrochemical sensors, digital displays, simple installation, and end-of-life warnings, these alarms demonstrate a commitment to both safety and user convenience, making them a critical component in home safety protocols.