Vector VEC021 Charging/Recharging, Volt AC Charging, Battery Replacement, Battery Disposal

Page 7

6

NOTE: In the rare event that the vehicle to be started has a Positive Grounded System (positive battery terminal is connected to chassis): Replace steps I and 2 above with the following steps, and then proceed to steps 4-6 above.

1.Connect negative (-) black clamp to vehicle battery ‘s negative terminal.

2.Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal vehicle component or body part. DO NOT clamp directly to positive battery terminal or moving part.

CAUTIONS:

If vehicle fails to start, leave vehicle ignition key turned OFF, turn INDUSTRIAL 900™ power switch to off, disconnect the negative (-) clamp first, then the positive (+) clamp, and discontinue jumpstarting procedure.

Recharge jumpstart system after each use.

WARNINGS:

ALWAYS disconnect the negative (Black) jumper cable first; followed by the positive (Red) jumper cable.

NEVER ALLOW RED AND BLACK CLAMPS TO TOUCH EACH OTHER OR ANOTHER COMMON METAL CONDUCTOR—THIS COULD CAUSE DAMAGE TO THE UNIT AND/OR CREATE A SPARK AND EXPLOSION.

There is a risk of explosive gases being released when batteries are improperly charged or discharged. Failure to follow instructions may cause property damage, explosive hazard, and/or personal injury.

ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY ACID MAY CAUSE BLINDNESS AND/OR SEVERE BURNS.

Keep out of reach of children.

ALWAYS store battery clamps in built-in holsters when not in use. Never touch battery clamps together—this can cause dangerous sparks, power arcing, and/or explosion.

FIRST AID:

7

3. EMERGENCY/WORK LIGHT

Bulb Replacement

To turn work light on or off, simply toggle the switch on the front control panel.

1.Replacement bulbs are available from Vector™ Customer Service Department; call (954) 923-1155.

2.Remove the lens cover, two phillips type screws—snap out cover.

3.Remove the burned-out bulb.

4.Replace with a new bulb (12-volt 0.7 amp Krypton bulb).

5.Snap the lens cover back into place and replace the two screws—DO NOT OVER-TIGHTEN.

4. CHARGING/RECHARGING

4.1110-Volt AC Charging

IMPORTANT:

• MAKE SURE SAFETY ON/OFF SWITCH IS IN OFF POSITION DURING RECHARGING.

• Charge unit for full 24 hours, prior to first use.

• Recharge unit fully after each use.

• Recharge unit every two months, when it has not been used.

1.Simply plug the 110-volt AC plug (Fig. 5 #1) of the AC/DC adapter/charger cord into any standard 110/120-volt AC wall outlet.

2.Plug the 12-volt DC cigarette type plug (Fig. 5 #2) into the 12-volt DC receptacle on the unit.

3.Charge this device for at least 14-16 hours or until the FULL indicator is lit.

4.NOTE: The unit can be overcharged (which will shorten the life of the battery)—DO NOT charge with AC charging procedure for more than 24 hours maximum.

5.Remove the power cord and store in a safe place.

6.When the 110-volt power inverter option is installed on the unit, the inverter ‘s ON/OFF switch must be in the OFF position during recharging.

Skin: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap and water. If redness, pain, or irritation occurs, SEEK IMMEDIATE MEDICAL ATTENTION.

Eyes: If battery acid comes in contact with eyes, flush eyes immediately—for minimum of 15 minutes—SEEK

IMMEDIATE MEDICAL ATTENTION.

2.2 BATTERY REPLACEMENT

Figure 5.

1. 3.

12-VOLT DC/DC

IT IS RECOMMENDED TO RETURN UNIT TO VECTOR™ CUSTOMER SERVICE FOR BATTERY REPLACEMENT: CONTACT (954) 923-1155

2.3 BATTERY DISPOSAL

Contains a maintenance-free, sealed, non-spillable, lead acid battery which must be disposed of properly. Most states require recycling—contact your local authority for information.

SEALED LEAD BATTERY, MUST BE RECYCLED OR DISPOSED OF PROPERLY, DISPOSAL QUESTION? FOR USA CALL 1-800-RE-USE-PB (738-7372) OR VECTOR™ CUSTOMER SERVICE.

WARNINGS:

DO NOT DISPOSE OF THE BATTERY IN FIRE AS THIS MAY RESULT IN AN EXPLOSION.

BEFORE DISPOSING OF THE BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-DUTY ELECTRICAL TAPE TO PREVENT SHORTING (SHORTING CAN RESULT IN INJURY OR FIRE).

DO NOT EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY EXPLODE.

CHARGING CORD

110-VOLT AC/DC

ADAPTER/CHARGER

4.

2.

4.2 12-Volt DC Charging

The INDUSTRIAL 900™ system also comes with a DC/DC charging cord, for recharging the unit from the 12-volt DC cigarette lighter socket in a vehicle or boat. Note: This recharging method will NOT recharge the unit as effectively as recharging from a 110-volt AC outlet. The 12-volt DC recharging procedure is recommended only when it is necessary, as continued use of the 12-volt DC recharging procedure may shorten the battery system’s life.

Image 7
Contents 900 Table of Contents First AID Battery ReplacementBattery Disposal Jumpstart System AND/OR the Power Force InverterHEAVY-DUTY, 600 AMP Copper Clamps CHARGER/POWER CordWORK/EMERGENCY Light ON/OFF Switch Charge Status Button HEAVY-DUTY #4AWGFirst AID FeaturesSafety Warnings Important InformationEASY, STEP-BY-STEP Jumpstarting Instructions Using the Industrial 900 AS a Jumpstart System110-Volt AC Charging Battery ReplacementBattery Disposal CHARGING/RECHARGINGRecharging Table I. Estimated Battery LifeReplacement Parts SpecificationsIntroduction Installation Operating Tips TroubleshootingLength Product SpecificationsTroubleshooting Guide LOW Output Voltage TV, Power Tool will not Start UPFT. LAUDERDALE, FL Year Limited Warranty Registration Form